Vents VUE 300 HBE EC A21

Vents VUE 300 HBE EC A21 - Heat recovery air handling units in sound- and heat-insulated casings equipped with an enthalpy counter-flow heat exchanger
Heat recovery air handling units in sound- and heat-insulated casings equipped with an enthalpy counter-flow heat exchanger
  • Power of electrical reheater: 2800 W
  • Maximum airflow: 380 m3/h
  • Sound pressure level LpA at 3 m: 24 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4+F7
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass
  • Reheater: Electric
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Galvanized steel
  • Humidity sensor
  • CO2 sensor
  • VOC sensor
  • PM2.5 sensor
Unit of measurement VUE 300 HBE EC A21
Connected air duct size mm 160
Speed - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 182
Power of electrical reheater W 2800
Unit current A 13.6
Maximum airflow m3/h 380
rotation speed at 50hz - 2100
Sound pressure level LpA at 3 m dB(A) 24
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 64.3
Extract filter - G4
Supply filter - G4+F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
ambient air temperature min °С 1
ambient air temperature max °С 40
ambient air humidity max % 80
Ingress protection rating - IP22
Passport
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Passport
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Printing
"VENTS VUT/VUE HB/HBE EC" product description 01-2023
2.47 Mb
Passport
"VENTS VUT/VUE HB/HBE EC" user's manual 11-2023 (V109-2EN-01)
4.42 Mb
Photos
VUT-HB-EC-800x800.png
444 Kb
Vents VUE 300 HBE EC A21 - Dimensions
ØD B B1 B2 H H1 H2 L L1
157 568 190 189 479 193 118 1083 1180
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Vents DPWC11200 DPWC11200 Humidity sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents NKP 160-0,8-1 A21 V.2 NKP 160-0,8-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,2-1 A21 V.2 NKP 160-1,2-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,7-1 A21 V.2 NKP 160-1,7-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-2,0-1 A21 V.2 NKP 160-2,0-1 A21 V.2 Heater for heat exchanger freeze protection
Name Photo Description
Vents SR 160/600 SR 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/900 SR 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/1200 SR 160/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 160/600 SRF 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 160/900 SRF 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 160/2000 SRF 160/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 160 KOM 160 Spring-loaded backdraft damper for round ducts
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents DN-2 DN-2 The drain pump provides extraction and discharge of condensate in ventilation systems
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 484x178x48 G4 SF 484x178x48 G4 Panel filter G4
Vents SF 484x178x48 F7 SF 484x178x48 F7 F7 panel filter