Unit of measurement | VUE 300 HBE EC A21 | |
Connected air duct size | mm | 160 |
Speed | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 182 |
Power of electrical reheater | W | 2800 |
Unit current | A | 13.6 |
Maximum airflow | m3/h | 380 |
rotation speed at 50hz | - | 2100 |
Sound pressure level LpA at 3 m | dB(A) | 24 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Enthalpy |
Weight | kg | 64.3 |
Extract filter | - | G4 |
Supply filter | - | G4+F7 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
ambient air temperature min | °С | 1 |
ambient air temperature max | °С | 40 |
ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
ØD | B | B1 | B2 | H | H1 | H2 | L | L1 |
---|---|---|---|---|---|---|---|---|
157 | 568 | 190 | 189 | 479 | 193 | 118 | 1083 | 1180 |
Name | Photo | Description |
---|---|---|
Vents A25 | The control panel with a sensor display | |
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats | |
Vents DPWC11200 | Humidity sensor |
Name | Photo | Description |
---|---|---|
Vents DPWQ30600 | VOC sensors | |
Vents DPWQ40200 | CO2 sensor |
Name | Photo | Description |
---|---|---|
Vents NKP 160-0,8-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,2-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-1,7-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 160-2,0-1 A21 V.2 | Heater for heat exchanger freeze protection |
Name | Photo | Description |
---|---|---|
Vents SR 160/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 160/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 160/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 160/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 160/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 160 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 160 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents DN-2 | The drain pump provides extraction and discharge of condensate in ventilation systems |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions | |
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 484x178x48 G4 | Panel filter G4 | |
Vents SF 484x178x48 F7 | F7 panel filter |