Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Supply and exhaust units
  • Air handling units with heat recovery
  • Air Handling Units AirVENTS
  • Energy saving inline units X-VENT
  • Geothermal ventilation systems
Additionally
Show ×
Air capacity
Mounting
Type
Connection diameter
Duct
Casing material
Height
Width
Heating
Hide filters
Error
%
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Print version
Search results
Selected products
Mode CurrentSound pressure level at 3 m distanceWeightSound pressure level at 3 m distanceFan currentElectric heater powerHeat recovery efficiencyPowerAir capacityHeat recoveryVoltageMaximum fan powerFan currentElectric heater currentNumber of electrical heating elementsTotal unit powerTotal unit currentMaximum air capacity RPMNoize level at 3 mMaximum transported air temperatureCasing materialInsulationFilterConnected air duct diameterMassNumber of water (glycol) coil rowsPhaseHeater typeNumber of rows in water heaterFilter: extractFilter: supplyHeat recovery efficiencyHeat exchanger materialTypeFrequencyEngine TypeUnit voltageMaximum unit currentMaximum unit powerWater cooler block (not included delivery)DX cooler block (not included delivery)Max. unit power without electric heaterMax. unit current without electric heaterMax. unit power with electric heaterMax. unit current with electric heaterMaximum unit currentSEC ClassDuct diameterHeatingWidthHeightCasing materialDuctConnection diameterTypeMountingMaximum transported air temperatureSound pressure level at 3 m distanceInsulationHeat recovery efficiencyHeat exchanger typeHeat exchanger materialMaximum fan powerFan currentPM 2.5 filtration efficiencyHumidity recovery efficiencyTransported air temperatureRegeneration efficiencyAir capacityFilterHeat recovery efficiencySEC class for A2Maximum fan powerTransported air temperatureFan currentSEC class for A14, A21
- - 30-45 67 - - - - - - - 220-240 - - - - - - 400 2600 - - - - - 200 - - 1 - - G4 G4 , F7 - - - 50/60 - - - 210 - - - - - - 1.6 A - - - - aluzinc - - - - - - 25 mm mineral wool 76...95 counter-flow enthalpy - - - - - - - - - - - - - -
- - - - - - - - - - - 220-240 - - - - 350 2.6 550 2150 - - - - - 200 40 2 1 - - G4 F7 (EU7) - - - 50/60 - - - - - - - - - - - A - - - - aluzinc - - - - - 28-47 25 mm mineral wool 93 counter-flow enthalpy 2 х 175 2 х 1.3 - - - - - - - - - - - -
- - - 57 - - - - - - - 230 - - - - - - - 3200 - - - - - - - - 1 - - G4 F7 (G4*) - - - 50/60 - - - 169 - - - - - - 1.3 A - without heating - - painted steel - 160 - floor mounting , wall mounting - 28 40 mm mineral wool 74...91 counter-flow enthalpy - - - - -25 ... +40 - 420 - - - - - - -
- - - - 65 - - 78 - 2100 - 230 - - - - 1300 5.68 - 1150 - - - - - 315 99 4 1 - - G4 G4 - - - 50 - - - - - - - - - - - - - water heating - - aluzinc - - supply and exhaust with heat recovery floor mounting -25..+40 - 50 mm mineral wool - cross-flow polystyrol - - - - - - - - - - 2 pcs. x 650 - 2 pcs. x 2.84 -
- - - - - - - - - 300 - 230 - - - - - - - - - - - EPP 15…26 mm - 125 13.5 - 1 - - G4 G4 , F8 - - - 50/60 - - - 162 - - - - - - 1.2 - - - - - expanded polypropylene - - - - - 34 - 72...94 counter-flow enthalpy - - - - -25 ... +40 - - - - В - - - A
- - - - - - - - - 3250 - 400 Y 1270 2.3 - - 1270 2.3 3250 1200 53 -40 +45 aluzinc 25 mm, mineral wool G4 600х350 73.1 4 3 water - - - - - приточная 50 380В / 50Гц - - - - - - - - - - - - water heating 600 350 - for rectangular air ducts - - - - - - - - - - - - - - - - - - - - - - -
- - - - 52 2,26 3,3 - - - - 230 - - 14.3 - 3700 16.56 1100 2780 - - - - - 250 95 - 1 - - G4 G4 (F7*) - - - 50/60 - - - - - - - - - - - - - - - - aluzinc - - - - - - 20 mm mineral wool - counter-flow aluminium 400 - - - - - - - up to 90 - - -25 up to +40 - -
- - - - 48 - - 78 - 780 - 230 - - - - 490 2.16 - 1650 - - - - - 250 88 2 1 - - G4 G4 - - - 50 - - - - - - - - - - - E - water heating - - aluzinc - - supply and exhaust with heat recovery floor mounting -25..+40 - 50 mm mineral wool - cross-flow polystyrol - - - - - - - - - - 2 pcs. x 245 - 2 pcs. x 1.08 -
- - - - 28-47 - - 88 - 530 - 230 - - - - 300 1.32 - 1100 - - - - - 160 49 - 1 - - G4 G4 - - - 50/60 - - - - - - - - - - - E - without heating - - aluzinc - - supply and exhaust with heat recovery floor mounting -25..+40 - 25 mm mineral wool - cross-flow polystyrol - - - - - - - - - - 2 pcs. x 150 - 2 pcs. x 0.66 -
- - 35 - - - - - - - - 230 - - - - - - - 2317 - - - - - 150 14 - 1 - - G4 G4 (F7*) - - - 50/60 - - - 117 - - - - - - 0.54 D - - - - expanded polypropylene - - - - - - EPP 30-15 mm 86...98 counter-flow polystyrol - - - - -25 ... +60 - 220 - - - - - - -
- 0.63 - - - - - - 141 - - 220-240 - - - - - - - 2840 - - - - - 100 24 - 1 - - G4 G4 и F8 (PM2.5 93 %) - - - 50 - - - - - - - - - - - D - - - - painted steel - - - - - 49 5 mm, 10 mm polyurethane foam - cross-flow enthalpy - - - 27...47 -25 ... +40 72...87 280 - - - - - - -
- - 26 - - - - - - - - 230 - - - - - - 190 3770 - - - - - 125 48 - 1 - - G4 F7 - - - 50/60 - - - 50 - - - - - - 0.4 A+ - - - - galvanized steel - - - - - - 40 mm mineral wool 82...94 counter-flow aluminium - - - - - - - - - - - - - -
- - 64 - - - - - - - - 230 - - - - 1070 5 2250 3000 - - - - - 500х300 198 - 1 - - G4 G4 - - - 50/60 - - - - - - - - - - - - - - - - aluzinc - - - - - - 25 mm mineral wool 68...93 rotary aluminium 2 x 448 - - - -25 ... +40 - - - - - - - - -
- - - - - - - - - - - 220-240 - - - - 140 1.2 300 1380 - - - - - 150 40 2 1 - - G4 F7 (EU7) - - - 50/60 - - - - - - - - - - - A+ - - - - aluzinc - - - - - 24-45 25 mm mineral wool 93 counter-flow enthalpy 2 х 70 2 х 0.6 - - - - - - - - - - - -
- - - 51 - - - - - - - 230 - - - - - - - 2050 - - - - - - - - 1 - - G4 G4 , F7 - - - 50/60 - - - 115 - - - - - - 0.9 A+ - without heating - - painted steel - 160 - floor mounting , wall mounting - 25 30 mm mineral wool 85...94 counter-flow polystyrol - - - - -25 ... +40 - 290 - - - - - - -
- - 62 - - - - - - - - 230 - - - - 750 3.2 1500 2000 - - - - - 315 175 - 1 - - G4 G4 - - - 50/60 - - - - - - - - - - - - - - - - aluzinc - - - - - - 20 mm mineral wool 72...95 rotary aluminium 2 x 222 - - - -25 ... +40 - - - - - - - - -
A2 - - - - - - - - - - 230 - - - - - - - 2200 - - - - - 150 14 - 1 - - G4 G4 , F7 - - - 50/60 - - - 87 - - - - - - 0.71 A - - - - expanded polypropylene - - - - - 33 EPP 30-15 mm 86...98 counter-flow polystyrol - - - - -25 ... +40 - 220 - - - - - - -
A14 - - - - - - - - - - 230 - - - - - - - 2200 - - - - - 150 14 - 1 - - G4 G4 , F7 - - - 50/60 - - - 87 - - - - - - 0.71 A+ - - - - expanded polypropylene - - - - - 33 EPP 30-15 mm 86...98 counter-flow polystyrol - - - - -25 ... +40 - 220 - - - - - - -
A21 - - - - - - - - - - 230 - - - - - - - 2200 - - - - - 150 14 - 1 - - G4 G4 , F7 - - - 50/60 - - - 87 - - - - - - 0.71 A+ - - - - expanded polypropylene - - - - - 33 EPP 30-15 mm 86...98 counter-flow polystyrol - - - - -25 ... +40 - 220 - - - - - - -
- - - - - 0.55 - - - 1200 - 400 - - - - 320 0.55 1200 2700 - - - - - 400х200 55 2 3 - 2-двухрядный - - - - - 50 - - - - - - - - - - - - - water heating 400 200 aluzinc for rectangular air ducts - - - - 51 50 mm mineral wool - - - 320 - - - -25 ... +55 - - G4 (F7) pocket type* - - - - - -
- - - - - 1.34 9000 - - 1520 - 400 - - 13 3 9296 14.34 - 2720 - - - - G4 315 62 - 3 - - - - - - - 50 - - - - - - - - - - - - 315 - - - aluzinc for round air ducts - - - - 30 25 mm mineral wool - - - 296 - - - -25 ... +45 - - - - - - - - -
- - - - - - - - - - - 220-240 - - - - - - - 3600 - - - - - - 104 - 1 - - G4 G4 , F7 , * H13 - - - 50/60 - - - - - - 367 2.5 3167 13.7 - A - electric heating - - galvanized steel - 200 - floor mounting , wall mounting , ceiling mounting - 36 40 mm mineral wool 80...87 rotary aluminium - - - - - - 710 - - - - - - -
- 0.33 - - - - - - 76 - - 220-240 - - - - - - - 2750 - - - - - 100 17 - 1 - - G4 G4 и F8 (PM2.5 93 %) - - - 50 - - - - - - - - - - - D - - - - painted steel - - - - - 47 5 mm, 10 mm polyurethane foam - cross-flow enthalpy - - - 32...47 -25 ... +40 75...87 160 - - - - - - -
- - - - - - - - - - 1 - - - - - - - 3000 - - -25 +60 aluzinc 50 mm, mineral wool - 600х350 - - 3 - - кассетный G4 кассетный G4 и карманный F7 65 алюминий - 50 380В / 50Гц 400 4 2520 C3/AVU 03/О DX3/AVU 03/О - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 1.1 52 - - - - - 250 - - 230 - - - - - - - 2400 - - - - - 150 29 - 1 - - G4 G4 , F8 - - - 50/60 - - - - - - - - - - - E - - - - painted steel - - - - - - 5 mm, 10 mm polyurethane foam - cross-flow polymerized cellulose - - 83 22...32 - 66...76 370 - - - - - - -
- - 28 55 - - - - - 380 - 230 - - - - - - - 3200 - - - - - 160 - - 1 - - G4 G4 , F7 - - - 50/60 - - 1.3 170 - - - - - - - A - - - - painted steel - - - - - - 40 mm mineral wool 84...94 counter-flow polystyrol - - - - -25 ... +40 - - - - - - - - -
- - - 45 - - - - - - - 230 - - - - - - - 2050 - - - - - - - - 1 - - G3 G3 - - - 50/60 - - - 112 - - - - - - 0.9 A - without heating - - painted steel - 125 - floor mounting , wall mounting - 24 25 mm mineral wool 74...94 counter-flow enthalpy - - - - -25 ... +40 - 250 - - - - - - -
Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
Basic parameter for domestic fan selection