AirVENTS AVS: The new generation of professional ventilation
Commercial air handling units with extended possibilities
Air flow capacity: 1 000 – 20 000 m³/h
Modular frameless casing design
Integrated control system
Wide range of rotary and plate heat exchangers
Sizes and capacities of AirVENTS AVS units
Improved design with better performance
T2 / TB2 / L1 / D1
The construction of the case with a PVC profile ensures the absence of
thermal bridges, minimizes heat loss and reduces the noise level.
Heat exchangers
Heat exchanger efficiency up to 90 % – efficient in
energy saving and reducing ventilation system costs.
Air handling units with a sorption rotor have high
efficiency and keep comfortable humidity with
low risk of frosting.
High-efficient counter-flow heat exchangers with
lower pressure losses. As standard, the regenerators
are equipped with a bypass damper.
Fans with ultra premium class motors and FanGrids
Electronically commutated direct current motors
(EC motors) with an external rotor, equipped with
a backward curved impeller, are used.
Such motors
with an IE5 class are the most progressive solution
for energy saving.
In FanGrids, multiple small fans operate in parallel,
rather than having one large fan. This provides
redundancy, ensuring fail-safe operation.
Modular design allows:
combining sections fast without leakages
optimizing manufacturing time
making transportation easier
Integrated control system
Plug-and-play unit: full electric wiring
Additional option – full factory electric wiring
includes:
Installation of air damper actuators. Routing of
contacts from actuators to the terminal box.
Installation of differential pressure switches in
filter sections. Installation of a relay actuation
threshold to the necessary level (final pressure
drop according to the selection).
Installation of frost protection thermostats in
water heating coils sections.
Installation of the VFD in the rotary heat
exchanger section.
Installation of bypass damper actuators in the
plate heat exchanger section.
Routing of all electric contacts in the electric
heater sections.
Routing of all electric contacts in the fan sections.
Installation and adjustment of all temperature
and humidity sensors inside the unit.
All the electric contacts are routed to the junction
box, which is mounted in one of the sections.
Plug-and-play option implies the possibility of
shipment in separate blocks. In this case, joints
and connection boxes are installed between the
sections.
Building Management Systems
AirVENTS AVS units control system can be easily
integrated into building management systems (SCADA, BMS, «smart house»).
All the information processed by a programmable logic controller, is easily
accessible via standard communication protocols:
MODBUS TCP;
LON WORKS.
Any other protocol can be used a ccording to customer’s choice and project
requirements.