Vents 100 M TH

Axial fans for exhaust ventilation
  • Maximum airflow: 102 m3/h
  • Sound pressure level LpA at 3 m: 38 dB(A)
  • Motor type: AC
  • Casing material: Plastic
  • Backdraft protection: Backdraft damper
  • Motion sensor
  • Pull cord
  • Humidity sensor
Unit of measurement 100 M TH
Connected air duct size mm 100
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 14
Unit current A 0.085
Maximum airflow m3/h 102
Sound pressure level LpA at 3 m dB(A) 38
Weight kg 0
Ambient air temperature min °С 0
Ambient air temperature max °С 0
Ingress protection rating - IP34
Trademark Vents
Model 100 M TH
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-52.5 A+ -25.4 C -9.9 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 98
Electric power input (W) 14
Reference flow rate (m3/s) 0.019
Specific power input (SPI) (W/(m3/h)) 0.143
Control typology Local demand control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 54
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
116 116 116
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5536 2830 1280
Datasheet
"VENTS M" product description 08-2018
5.41 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
BIM/CAD models
M
1.21 Mb
Image
100 M TH - image 1
558 Kb
∅D B H L L1
100 159 135 88.5 23
Name Photo Description
Vents KO 100 KO 100 Back valve is designed for domestic fan series VENTS M, M1, D, S, M3, X, X1, LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro star, Z star, X star
Vents FO 100 FO 100 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF