Vents 100 Silenta-STH

Low noise and low watt axial fans for exhaust ventilation
  • Maximum airflow: 78 m3/h
  • Sound pressure level LpA at 3 m: 26 dB(A)
  • Motor type: AC
  • Impeller type: Axial
  • Casing material: Plastic
  • Humidity sensor
  • Timer: Turn off timer
Unit of measurement 100 Silenta-STH
Connected air duct size mm 100
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Rated power W 7
Unit current A 0.035
Maximum airflow m3/h 78
Sound pressure level LpA at 3 m dB(A) 26
Weight kg 0.52
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 100 Silenta-STH
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-54.2 A+ -27.1 B -11.6 E
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 78
Electric power input (W) 7
Reference flow rate (m3/s) 0.015
Specific power input (SPI) (W/(m3/h)) 0.058
Control typology Local demand control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 46
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
47 47 47
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5536 2830 1280
Datasheet
"VENTS Silenta-S" product description 05-2022
3.48 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Image
100 Silenta-STH - image 1
591 Kb
Ø D B H L L1
100 150 120 108 12