Vents 100 Style TH

Innovative domestic extract fan with automatic shutters, low-noise operation and low energy consumption
  • Maximum airflow: 97 m3/h
  • Sound pressure level LpA at 3 m: 25 dB(A)
  • Motor type: AC
  • Casing material: Plastic
  • Humidity sensor
  • Timer: Turn off timer
Unit of measurement 100 Style TH
Connected air duct size mm 100
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 9
Unit current A 0.059
Maximum airflow m3/h 97
Sound pressure level LpA at 3 m dB(A) 25
Weight kg 0.55
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP44
Trademark Vents
Model 100 Style TH
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-53.5 A+ -26.4 B -10.9 E
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 97
Electric power input (W) 9
Reference flow rate (m3/s) 0.019
Specific power input (SPI) (W/(m3/h)) 0.093
Control typology Local demand control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 45
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
76 76 76
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5536 2830 1280
Datasheet
"VENTS Style" product description 12-2022
2.27 Mb
Manual
"VENTS Style" user's manual 11-2022 (V164EN-05)
1.61 Mb
BIM/CAD models
Style
1.8 Mb
Image
100 Style TH - image 1
364 Kb
Vents 100 Style TH - Dimensions
Ø d a b c e
99 175 221 77 39
Name Photo Description
Vents FO 100 FO 100 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF