Vents 125 F turbo

Axial fans for exhaust ventilation
  • Maximum airflow: 232 m3/h
  • Sound pressure level LpA at 3 m: 37 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 125 F turbo
Connected air duct size mm 125
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Rated power W 24
Unit current A 0.1
Maximum airflow m3/h 232
Sound pressure level LpA at 3 m dB(A) 37
Weight kg 0.77
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 125 F turbo
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-31 B -15 E -6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 232
Electric power input (W) 24
Reference flow rate (m3/s) 0.045
Specific power input (SPI) (W/(m3/h)) 0.067
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 57
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
"VENTS F" product description 05-2022
2.18 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Image
125 F turbo - image 1
475 Kb
Ø D B B1 B2 H H1 L L1
125 182 152 160 252 226 110 15
Name Photo Description
Vents FO 125 FO 125 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF