Vents 125 LD Q

Axial decorative fans for exhaust ventilation
  • Maximum airflow: 108 m3/h
  • Sound pressure level LpA at 3 m: 31 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 125 LD Q
Connected air duct size mm 125
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 9.3
Unit current A 0.06
Maximum airflow m3/h 108
Sound pressure level LpA at 3 m dB(A) 31
Weight kg 0.74
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 125 LD Q
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-30.9 B -14.5 E -5.1 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 108
Electric power input (W) 9.3
Reference flow rate (m3/s) 0.021
Specific power input (SPI) (W/(m3/h)) 0.086
Control typology Manual control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 51
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
108 108 108
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS LD" product description 04-2020
4.18 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
BIM/CAD models
LD
1.5 Mb
Image
125 LD Q - image 1
529 Kb
Image
125 LD Q - image 2
740 Kb
Image
125 LD Q - image 3
641 Kb
Image
125 LD Q - image 4
569 Kb
Image
125 LD Q - image 5
698 Kb
Image
125 LD Q - image 6
476 Kb
Vents 125 LD Q - Dimensions
∅D B H L L1
125 177 140 135 34
Name Photo Description
Vents FO 125 FO 125 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF
Vents KO 125 KO 125 Back valve is designed for domestic fan series VENTS M, M1, D, S, M3, X, X1, LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro star, Z star, X star