Vents 125 M1 12

Axial fans for exhaust ventilation
  • Maximum airflow: 165 m3/h
  • Sound pressure level LpA at 3 m: 34 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 125 M1 12
Connected air duct size mm 125
Minimum supply voltage V 12
Maximum supply voltage V 12
Power supply frequency Hz 50
Rated power W 16
Unit current A 1.7
Maximum airflow m3/h 165
Sound pressure level LpA at 3 m dB(A) 34
Weight kg 0.68
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 125 M1 12
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-32 B -15 E -6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 165
Electric power input (W) 16
Reference flow rate (m3/s) 0.032
Specific power input (SPI) (W/(m3/h)) 0.062
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 54
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
"VENTS M1" product description 09-2015
4.57 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Manual
"VENTS domestic fans" user's manual 01-2022 (V01EN_16-01)
5.24 Mb
Image
125 M1 12 - image 1
596 Kb
Vents 125 M1 12 - Dimensions
∅D B B1 B2 H L L1
125 190 174 128 173 98 33
Name Photo Description
Vents FO 125 FO 125 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF
Vents KO 125 KO 125 Back valve is designed for domestic fan series VENTS M, M1, D, S, M3, X, X1, LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro star, Z star, X star