Vents 125 PF L

Axial fans for extract ventilation with round grilles
  • Sound pressure level LpA at 3 m: 35 dB(A)
  • Casing material: Plastic
  • Ball bearing
Unit of measurement 125 PF L
Connected air duct size mm 125
Phases - 1
Maximum supply voltage V 240
Minimum supply voltage V 220
Power supply frequency Hz 50/60
Rated power W 16
Unit current A 0.1
Maximum airflow m³/h 185
Rotation speed at 50hz - 2400
Sound pressure level LpA at 3 m dB(A) 35
Weight kg 0.58
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Impeller material - Plastic
Trademark Vents
Model 125 PF L
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-30.8 B -14.4 E -5 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m³/h) 185
Electric power input (W) 16
Reference flow rate (m³/s) 0.036
Specific power input (SPI) (W/(m³/h)) 0.086
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 55
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
108 108 108
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS PF" product description 01-2024
2.2 Mb
Manual
"VENTS PF (127-220 V/60 Hz)" user's manual 10-2020 (V202-3EN-01)
1.19 Mb
Manual
"VENTS domestic fans" user's manual 06-2025 (V01EN_16-01)
4.08 Mb
Image
125 PF L - image 1
596 Kb
Ø D Ø D1 L L1
125 166 110 15