Vents 125 PF press

Axial fans for exhaust ventilation with air capacity up to 342 m³/h
  • Maximum airflow: 188 m3/h
  • Sound pressure level LpA at 3 m: 39 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 125 PF press
Connected air duct size mm 125
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Rated power W 24
Unit current A 0.105
Maximum airflow m3/h 188
Sound pressure level LpA at 3 m dB(A) 39
Weight kg 0.58
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 125 PF press
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-29.6 B -13.2 E -3.8 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 188
Electric power input (W) 24
Reference flow rate (m3/s) 0.037
Specific power input (SPI) (W/(m3/h)) 0.128
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 59
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
160 160 160
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS PF" product description 05-2022
2.4 Mb
Manual
"VENTS PF (127-220 V/60 Hz)" user's manual 10-2020 (V202-3EN-01)
1.19 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Image
125 PF press - image 1
596 Kb
Ø D Ø D1 L L1
125 166 110 15
Name Photo Description
Vents FO 125 FO 125 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF