Vents 150 LD Light

Exhaust axial decorative fans
  • Maximum airflow: 265 m3/h
  • Sound pressure level LpA at 3 m: 37 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 150 LD Light
Connected air duct size mm 150
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 24
Unit current A 0.13
Maximum airflow m3/h 265
Sound pressure level LpA at 3 m dB(A) 37
Weight kg 1.14
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Trademark Vents
Model 150 LD Light
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-32 B -15 E -6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 265
Electric power input (W) 24
Reference flow rate (m3/s) 0.052
Specific power input (SPI) (W/(m3/h)) 0.058
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 57
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
"VENTS LD Light" product description 05-2022
3.58 Mb
Image
150 LD Light - image 1
519 Kb
Ø D B L L1
150 216 154 118
Name Photo Description
Vents FO 150 FO 150 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF