| Unit of measurement | 150 LD TH 12 | |
| Connected air duct size | mm | 150 |
| Phases | - | 1 |
| Minimum supply voltage | V | 12 |
| Maximum supply voltage | V | 12 |
| Power supply frequency | Hz | 50 |
| Rated power | W | 29 |
| Unit current | A | 2 |
| Maximum airflow | m³/h | 236 |
| Rotation speed at 50hz | - | 2300 |
| Sound pressure level LpA at 3 m | dB(A) | 36 |
| Weight | kg | 0.92 |
| Ambient air temperature min | °С | 1 |
| Ambient air temperature max | °С | 40 |
| Ingress protection rating | - | IP34 |
| Impeller material | - | Plastic |
| Trademark | Vents | |||||
| Model | 150 LD TH 12 | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -52.9 | A+ | -25.8 | C | -10.3 | E | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Single speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 236 | |||||
| Electric power input (W) | 29 | |||||
| Reference flow rate (m³/s) | 0.046 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.123 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 56 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 100 | 100 | 100 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents KO 150 |
|
Back valve is designed for domestic fan |
| Vents FO 150 |
|