Vents 150 M 12

High-performance axial extract fans
  • Sound pressure level LpA at 3 m: 38 dB(A)
  • Casing material: Plastic
Unit of measurement 150 M 12
Connected air duct size mm 150
Phases - 1
Minimum supply voltage V 12
Maximum supply voltage V 12
Power supply frequency Hz 50
Rated power W 29
Unit current A 2
Maximum airflow m³/h 263
Rotation speed at 50hz - 2300
Sound pressure level LpA at 3 m dB(A) 38
Weight kg 0.89
Ambient air temperature max °С 40
Ambient air temperature min °С 1
Ingress protection rating - IP34
Impeller material - Plastic
Trademark Vents
Model 150 M 12
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-30.1 B -13.7 E -4.3 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m³/h) 263
Electric power input (W) 29
Reference flow rate (m³/s) 0.051
Specific power input (SPI) (W/(m³/h)) 0.11
Control typology Manual control
Maximum external leakage rates (%) 2.7
Declared typology RVU UVU
Sound power level (dB(A)) 58
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
138 138 138
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS M" product description 01-2024
5.17 Mb
Manual
"VENTS domestic fans" user's manual 06-2025 (V01EN_16-01)
4.08 Mb
BIM/CAD models
M
1.21 Mb
Certificates
Certificate GS "MF 100 EC, M 100 EC"
1.76 Mb
Image
150 M 12 - image 1
558 Kb
∅D B H L L1
150 206 182 106 25.5
Name Photo Description
Vents KO 150 KO 150 Back valve is designed for domestic fan
Vents FO 150 FO 150 The window flange