Axial fans for exhaust ventilation
  • Maximum airflow: 341 m3/h
  • Sound pressure level LpA at 3 m: 40 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 150 S turbo
Connected air duct size mm 150
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 30
Unit current A 0.13
Maximum airflow m3/h 341
Sound pressure level LpA at 3 m dB(A) 40
Weight kg 1.13
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP34
Vents 150 S turbo 60 341 2016
Trademark Vents
Model 150 S turbo
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
30.8 B 14.4 E 5 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 341
Electric power input (W) 30
Reference flow rate (m3/s) 0.066
Specific power input (SPI) (W/(m3/h)) 0.088
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 60
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
110 110 110
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS S" product description 05-2022
3.66 Mb
Manual
"VENTS domestic fans" user's manual 01-2022 (V01EN_16-01)
5.24 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Manual
"VENTS S" user's manual 10-2022 (V202-2EN-01)
1.68 Mb
BIM/CAD models
S
2.27 Mb
Image
150 S turbo - image 1
582 Kb
Vents 150 S turbo - Dimensions
Ø D B H L L1
150 205 165 132 14