Vents 150 X1

Axial fans for exhaust ventilation
  • Maximum airflow: 295 m3/h
  • Sound pressure level LpA at 3 m: 37 dB(A)
  • Motor type: AC
  • Casing material: Plastic
Unit of measurement 150 X1
Connected air duct size mm 150
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 24
Unit current A 0.13
Maximum airflow m3/h 295
Sound pressure level LpA at 3 m dB(A) 37
Weight kg 0.92
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP24
Vents 150 X1 57 295 2016
Trademark Vents
Model 150 X1
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
32 B 16 E 6 F
Type of ventilation unit Unidirectional
Type of drive installed Multi-speed
Type of heat recovery system None
Maximum flow rate (m3/h) 295
Electric power input (W) 24
Reference flow rate (m3/s) 0.057
Specific power input (SPI) (W/(m3/h)) 0.052
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 57
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
100 100 100
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3400 1700 800
Datasheet
"VENTS X1" product description 05-2022
4.12 Mb
Manual
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01)
4.09 Mb
Manual
"VENTS domestic fans" user's manual 01-2022 (V01EN_16-01)
5.24 Mb
Image
150 X1 - image 1
567 Kb
Image
150 X1 - image 2
304 Kb
Vents 150 X1 - Dimensions
Ø D B H L L1
150 205 165 132 13
Name Photo Description
Vents FO 150 FO 150 The window flange applicable for all VENTS fans except for VKO, VKO1, iFan, Quiet, MAO, CF
Vents KO 150 KO 150 Back valve is designed for domestic fan series VENTS M, M1, D, S, M3, X, X1, LD, LD Fresh time, Silenta-M, Silenta-S, Modern, Vitro star, Z star, X star