Vents Alta 100 V L

Vents Alta 100 V L - Fans with automatic shutters for exhaust ventilation
Vents Alta 100 V L - Fans with automatic shutters for exhaust ventilation
Vents Alta 100 V L - Fans with automatic shutters for exhaust ventilation
New
Fans with automatic shutters for exhaust ventilation
  • Maximum airflow: 90 m3/h
  • Sound pressure level LpA at 3 m: 25 dB(A)
  • Motor type: AC
  • Impeller type: Mixed-flow
  • Casing material: ABS Plastic
  • Backdraft protection: Automatic shutters
  • Pull cord
Unit of measurement Alta 100 V L
Connected air duct size mm 100
Minimum supply voltage V 220
Maximum supply voltage V 240
Power supply frequency Hz 50
Rated power W 10
Unit current A 0.056
Maximum airflow m3/h 90
rotation speed at 50hz - 2300
Sound pressure level LpA at 3 m dB(A) 25
Weight kg 0.63
Transported air temperature (max) °С 40
Transported air temperature (min) °С 1
Ingress protection rating - IP24
Trademark Vents
Model Alta 100 V L
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-30.1 B -13.7 E -4.3 F
Type of ventilation unit Unidirectional
Type of drive installed Single speed
Type of heat recovery system None
Maximum flow rate (m3/h) 90
Electric power input (W) 10
Reference flow rate (m3/s) 0.018
Specific power input (SPI) (W/(m3/h)) 0.111
Control typology Manual control
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 45
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
139 139 139
The annual heating saved (AHS) (kWh/a) Cold Average Warm
3355 1715 776
Datasheet
"VENTS Alta" product description 09-2024
3.31 Mb
Manual
"VENTS Alta" user's manual 08-2024 (V274EN-02)
2.25 Mb
Image
Alta 100 V L - image 1
564 Kb
Image
Alta 100 V L - image 2
470 Kb
Image
Alta 100 V L - image 3
483 Kb
Vents Alta 100 V L - Dimensions
D B L L1
99 168 110 29
Name Photo Description