Unit of measurement | Boost-I 200 | |||
Connected air duct size | mm | 200 | ||
Speed | - | 1 | 2 | 3 |
Phases | - | 1 | ||
Minimum supply voltage | V | 230 | ||
Maximum supply voltage | V | 230 | ||
Power supply frequency | Hz | 50 | ||
Rated power | W | 82 | 104 | 113 |
Unit current | A | 0.37 | 0.46 | 0.51 |
Maximum airflow | m3/h | 692 | 906 | 1110 |
rotation speed at 50hz | - | 2229 | 2634 | 2823 |
Sound pressure level LpA at 3 m | dB(A) | 37 | 42 | 44 |
Weight | kg | 8.2 | ||
Transported air temperature (max) | °С | 55 | ||
Transported air temperature (min) | °С | -25 | ||
Ambient air temperature min | °С | 1 | ||
Ambient air temperature max | °С | 40 | ||
Ingress protection rating | - | IPX4 | ||
Ingress protection rating of the drive | - | IP20 |
Trademark | Vents |
Model | Boost-I 200 |
Type of drive installed | Integrated VSD |
Type of heat recovery system | None |
Nominal flow rate (m3/s) | 0.188 |
Nominal external pressure (Pa) | 177 |
Maximum external leakage rates (%) | 2.7 |
Static efficiency (%) | 31.9 |
Declared typology | NRVU UVU |
Effective electric power input (kW) | 0.106 |
Sound power level (dB(A)) | 62 |
Name | Photo | Description |
---|---|---|
Vents FBK 200-7 | Pocket filter | |
Vents FBK 200-5 | Pocket filter | |
Vents FBK 200-4 | Pocket filter | |
Vents FB 200 | Panel filters |
Name | Photo | Description |
---|---|---|
Vents TH-1,5 N | Sensor | |
Vents T-1,5 N | Sensor | |
Vents TP-1,5 N | Sensor | |
Vents TF-1,5 N | Sensor |
Name | Photo | Description |
---|---|---|
Vents P3-1-300 | Switch | |
Vents P2-1-300 | Switch |
Name | Photo | Description |
---|---|---|
Vents RTS-1-400 | Temperature regulator | |
Vents RTSD-1-400 | Temperature regulator |
Name | Photo | Description |
---|---|---|
Vents KR 200 | Air damper for air flow control in round air ducts | |
Vents KOMu 200 | Spring-loaded backdraft damper for round ducts | |
Vents KOM 200 | Spring-loaded backdraft damper for round ducts |
Name | Photo | Description |
---|---|---|
Vents NKV 200-2 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units | |
Vents NKV 200-4 | Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents NK 200-2,4-1 | Duct electric heater | |
Vents NK 200-2,0-1 | Duct electric heater | |
Vents NK 200-1,7-1 | Duct electric heater | |
Vents NK 200-1,2-1 | Duct electric heater | |
Vents NK 200-6,0-3 | Duct electric heater | |
Vents NK 200-5,1-3 | Duct electric heater | |
Vents NK 200-3,6-3 | Duct electric heater | |
Vents NK 200-3,4-1 | Duct electric heater |
Name | Photo | Description |
---|---|---|
Vents RS-1,5-PS | Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control | |
Vents RS-3,0-T | Applied in ventilation systems for speed switching ON/OFF and speed control of single-phase power-controlled motors | |
Vents RS-1-400 | Speed controller |