Vents Enave 180 P A21

Vents Enave 180 P A21 - Heat recovery air handling unit in sound- and heat-insulated casing made of expanded polypropylene
New
Heat recovery air handling unit in sound- and heat-insulated casing made of expanded polypropylene
  • Maximum airflow: 181 m3/h
  • Sound pressure level LpA at 3 m: 29 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: Coarse > 60 % (G4)
  • Supply filter: Coarse > 60 % (G4) (option ePM1 60 % (F7))
  • Sound insulation
  • Motor type: EC
  • Bypass: Auto
  • Reheater: Optional
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement Enave 180 P A21
Connected air duct size mm 160
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 53
Unit current A 0.49
Maximum airflow m3/h 181
Sound pressure level LpA at 3 m dB(A) 29
Heat recovery efficiency, max % 91
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 12
Extract filter - Coarse > 60 % (G4)
Supply filter - Coarse > 60 % (G4) (option ePM1 60 % (F7))
Transported air temperature (max) °С 45
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents Enave 180 P A21 49 153 2016
Trademark Vents
Model Enave 180 P A21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
82.1 A+ 43.2 A+ 18.2 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 87
Maximum flow rate (m3/h) 153
Electric power input (W) 53
Reference flow rate (m3/s) 0.03
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.204
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 49
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
690 153 108
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9060 4631 2094
Datasheet
"VENTS Enave P" product description 09-2024
1.93 Mb
Manual
"VENTS Enave P" user's manual 04-2024 (V278EN-01)
10.09 Mb
BIM/CAD models
Enave P
1.6 Mb
Image
Enave 180 P A21 - image 1
431 Kb
H W L D W1 L1
272 640 930 160 300 627
Other accessories
Name Photo Description
Vents SF 205x200x48 Coarse 90% G4 SF 205x200x48 Coarse 90% G4 Panel filter G4
Vents SF 205x200x48 ePM1 60% F7 SF 205x200x48 ePM1 60% F7 F7 panel filter
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents NKP 160-0,8-1 A21 V.2 NKP 160-0,8-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,2-1 A21 V.2 NKP 160-1,2-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,7-1 A21 V.2 NKP 160-1,7-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-2,0-1 A21 V.2 NKP 160-2,0-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKD 160-0,8-1 A21 V.2 NKD 160-0,8-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-1,2-1 A21 V.2 NKD 160-1,2-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-1,7-1 A21 V.2 NKD 160-1,7-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-2,0-1 A21 V.2 NKD 160-2,0-1 A21 V.2 Duct heater for supply air post-heating with external control
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Name Photo Description
Vents SR 160/600 SR 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/900 SR 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/1200 SR 160/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions