Unit of measurement | Enave 210 V A21 L | |
Connected air duct size | mm | 125 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 114 |
Unit current | A | 0.92 |
Maximum airflow | m3/h | 255 |
Sound pressure level LpA at 3 m | dB(A) | 34 |
Heat recovery efficiency, max | % | 92 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 20 |
Extract filter | - | G4 / Coarse > 60% |
Supply filter | - | G4 / Coarse > 60% (option F7 / ePM1 60%) |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Ø D | H | H1 | L | L1 | W | W1 |
---|---|---|---|---|---|---|
125 | 852 | 909 | 419 | 160 | 600 | 273 |
Name | Photo | Description |
---|---|---|
Vents SF 356x100x48 Coarse 90% G4 | Panel filter G4 | |
Vents SF 356x100x48 ePM1 65% F7 | F7 panel filter |
Name | Photo | Description |
---|---|---|
Vents A25 | The control panel with a sensor display | |
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-3 | CO2 sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats |
Name | Photo | Description |
---|---|---|
Vents NKP 125-0,6-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 125-0,8-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 125-1,2-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKD 125-0,6-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 125-0,8-1 A21 V.2 | Duct heater for supply air post-heating with external control | |
Vents NKD 125-1,2-1 A21 V.2 | Duct heater for supply air post-heating with external control |
Name | Photo | Description |
---|---|---|
Vents SH-32 | The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems |
Name | Photo | Description |
---|---|---|
Vents SR 125/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 125/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 125/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KRV 125 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |