Vents Enave-C 100 P A14

Vents Enave-C 100 P A14 - Heat recovery air handling units in sound- and heat-insulated casings
New
Heat recovery air handling units in sound- and heat-insulated casings
  • Maximum airflow: 130 m3/h
  • Sound pressure level LpA at 3 m: 32 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4 / Coarse > 60%
  • Supply filter: G4 / Coarse > 60% (option F7 / ePM1 60%)
  • Sound insulation
  • Motor type: EC
  • Control: Remote Control
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
Unit of measurement Enave-C 100 P A14
Connected air duct size mm 100/125
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 45
Unit current A 0.34
Maximum airflow m3/h 130
Sound pressure level LpA at 3 m dB(A) 32
Heat recovery efficiency, max % 94
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 8
Extract filter - G4 / Coarse > 60%
Supply filter - G4 / Coarse > 60% (option F7 / ePM1 60%)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -23
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents Enave-C 100 P A14 45 90 2016
Trademark Vents
Model Enave-C 100 P A14
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-81 A+ -42.3 A+ -17.5 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 86
Maximum flow rate (m3/h) 90
Electric power input (W) 37
Reference flow rate (m3/s) 0.018
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.254
Control typology Local demand control
Maximum internal leakage rates (%) 2.8
Maximum external leakage rates (%) 3
Declared typology RVU BVU
Sound power level (dB(A)) 45
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
716.4 179.4 134.4
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9019 4610 2085
Datasheet
"VENTS Enave-C 100 P A14" product description 09-2024
1.33 Mb
Manual
"Sensor control panel A14/A15" user’s manual 07-2024 (V55-7EN-02)
1.21 Mb
Manual
"VENTS Enave-C 100 P A14" user’s manual 10-2024 (V224EN-01)
2.49 Mb
BIM/CAD models
Enave-C(T) 100 P A14
999 Kb
Image
Enave-C 100 P A14 - image 1
826 Kb
ØD Ød H W L W1 B
125 104 247 522 530 600 630
Other accessories
Name Photo Description
Vents SF 176x160x22 G4 SF 176x160x22 G4 Panel filter G4
Vents SF 176x160x22 F7 SF 176x160x22 F7 F7 panel filter
Vents SF 176x150x22 F7 SF 176x150x22 F7 F7 panel filter
Vents SF 176x150x22 G4 SF 176x150x22 G4 Panel filter G4
Name Photo Description
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Vents HV2 HV2 Humidity sensor
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Name Photo Description
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions