| Unit of measurement | Enave-C 200 P A14 | |
| Connected air duct size | mm | 160/125 |
| Phases | - | 1 |
| Minimum supply voltage | V | 230 |
| Maximum supply voltage | V | 230 |
| Power supply frequency | Hz | 50/60 |
| Rated power | W | 111 |
| Unit current | A | 0.9 |
| Maximum airflow | m3/h | 279 |
| Sound pressure level LpA at 3 m | dB(A) | 33 |
| Heat recovery efficiency, max | % | 89 |
| Heat exchanger type | - | Counter flow |
| Heat exchanger material | - | Polystyrene |
| Weight | kg | 18 |
| Extract filter | - | G4 / Coarse > 60% |
| Supply filter | - | G4 / Coarse > 60% (option F7 / ePM1 60%) |
| Transported air temperature (max) | °С | 45 |
| Ambient air temperature min | °С | 1 |
| Ambient air temperature max | °С | 40 |
| Ambient air humidity max | % | 60 |
| Ingress protection rating | - | IP22 |
| Ingress protection rating of the drive | - | IP44 |
| Article | - | 8107078 |
| Trademark | Vents | |||||
| Model | Enave-C 200 P A14 | |||||
| Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
| -80.8 | A+ | -42.5 | A+ | -17.9 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | Recuperative | |||||
| Thermal efficiency of heat recovery (%) | 84 | |||||
| Maximum flow rate (m3/h) | 235 | |||||
| Electric power input (W) | 103 | |||||
| Reference flow rate (m3/s) | 0.046 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m3/h)) | 0.21 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 2.7 | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 54 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 693 | 156 | 111 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 8938 | 4569 | 2066 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents HV2 |
|
Humidity sensor |
| Vents CO2-1 |
|
CO2 sensors |
| Vents CO2-2 |
|
CO2 sensors |
| Vents HR-S |
|
Electro-mechanical humidistat |
| Name | Photo | Description |
|---|---|---|
| Vents SR 160/600 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 160/900 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 160/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Name | Photo | Description |
|---|---|---|
| Vents KRV 160 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents Belimo TF230 |
|
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
| Name | Photo | Description |
|---|---|---|
| Vents SF 200x165x48 Coarse 90% G4 |
|
Panel filter G4 |
| Vents SF 200x165x48 ePM1 65% F7 |
|
F7 panel filter |