Vents Enave-T 210 V A21 L

Vents Enave-T 210 V A21 L - Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
Coming soon
Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
  • Maximum airflow: 255 m3/h
  • Sound pressure level LpA at 3 m: 34 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4 / Coarse > 60%
  • Supply filter: G4 / Coarse > 60% (option F7 / ePM1 60%)
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Auto
  • Reheater: Optional
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement Enave-T 210 V A21 L
Connected air duct size mm 125
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 114
Unit current A 0.92
Maximum airflow m3/h 255
Sound pressure level LpA at 3 m dB(A) 34
Heat recovery efficiency, max % 83
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 20
Extract filter - G4 / Coarse > 60%
Supply filter - G4 / Coarse > 60% (option F7 / ePM1 60%)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS Enave 210 / 270 V" product description 02-2024
1.52 Mb
Manual
"VENTS Enave 210 / 270 V" user's manual 08-2024 (V282EN-01)
7.23 Mb
Image
Enave-T 210 V A21 L - image 1
591 Kb
Vents Enave-T 210 V A21 L - Dimensions
Ø D H H1 L L1 W W1
125 852 909 419 160 600 273
Other accessories
Name Photo Description
Vents SF 356x100x48 Coarse 90% G4 SF 356x100x48 Coarse 90% G4 Panel filter G4
Vents SF 356x100x48 ePM1 65% F7 SF 356x100x48 ePM1 65% F7 F7 panel filter
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents NKP 125-0,6-1 A21 V.2 NKP 125-0,6-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 125-0,8-1 A21 V.2 NKP 125-0,8-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 125-1,2-1 A21 V.2 NKP 125-1,2-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKD 125-0,6-1 A21 V.2 NKD 125-0,6-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 125-0,8-1 A21 V.2 NKD 125-0,8-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 125-1,2-1 A21 V.2 NKD 125-1,2-1 A21 V.2 Duct heater for supply air post-heating with external control
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions