Vents Enave-T 550 V A14 R

Vents Enave-T 550 V A14 R - Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
Coming soon
Heat recovery air handling units in sound- and heat-insulated casings made of expanded polypropylene
  • Maximum airflow: 660 m3/h
  • Sound pressure level LpA at 3 m: 57 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: Coarse > 60 %
  • Supply filter: Coarse > 60 % (option ePM1 60 %)
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Manual
  • Control: Wired control panel
  • Casing material: EPP
  • Humidity sensor: Optional
  • CO2 sensor: Optional
Unit of measurement Enave-T 550 V A14 R
Connected air duct size mm 200
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 347
Unit current A 2.4
Maximum airflow m3/h 660
Sound pressure level LpA at 3 m dB(A) 57
Heat recovery efficiency, max % 80
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 28
Extract filter - Coarse > 60 %
Supply filter - Coarse > 60 % (option ePM1 60 %)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS Enave 550 V" product description 02-2024
1.47 Mb
Manual
"VENTS Enave 350/550 V" user’s manual 09-2024 (V279EN-02)
8.88 Mb
Image
Enave-T 550 V A14 R - image 1
699 Kb
Ø D H H1 L L1 W W1
200 885 943 711 250 820 365
Other accessories
Name Photo Description
Vents SF 596x164x60 Coarse 90% G4 SF 596x164x60 Coarse 90% G4 Panel filter G4
Vents SF 596x164x60 ePM1 F7 SF 596x164x60 ePM1 F7 F7 panel filter
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-3 CO2-3 CO2 sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents SR 200/600 SR 200/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 200/900 SR 200/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 200/1200 SR 200/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 200 KRV 200 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions