Vents MPA 300 E-1.7 EC A31

Air supply units in the sound- and heat-insulated casing
  • Power of electrical reheater: 1700 W
  • Maximum airflow: 365 m3/h
  • Sound pressure level LpA at 3 m: 35 dB(A)
  • Filter: Coarse 90%/G4 (опція ePM1 70%/F7)
  • Sound insulation
  • Motor type: EC
  • Reheater: Electric
  • BMS protocol: ModBus
  • Control: Wired control panel
  • Casing material: Aluzinc steel
Unit of measurement MPA 300 E-1.7 EC A31
Connected air duct size mm 160
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 64
Power of electrical reheater W 1700
Unit current A 7.7
Maximum airflow m3/h 365
Sound pressure level LpA at 3 m dB(A) 35
Weight kg 24
Filter - Coarse 90%/G4 (опція ePM1 70%/F7)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -30
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents MPA 300 E-1.7 EC A31 35 220 2016
Trademark Vents
Model MPA 300 E-1.7 EC A31
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
53.9 A+ 26.8 B 11.3 E
Type of ventilation unit Unidirectional
Type of drive installed Variable speed
Type of heat recovery system None
Maximum flow rate (m3/h) 220
Electric power input (W) 64
Reference flow rate (m3/s) 0.058
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.114
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Sound power level (dB(A)) 35
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
60 60 60
The annual heating saved (AHS) (kWh/a) Cold Average Warm
5536 2830 1280
Datasheet
"VENTS MPA E EC A31" product description 08-2023
1.76 Mb
Manual
"Automatic control system A30, A31, A32" user’s manual 11-2023 (V201-1EN-01)
4.05 Mb
Manual
"VENTS MPA E EC A30/31/32" user's manual 09-2024 (V263EN-04)
2.57 Mb
BIM/CAD models
MPA 300-700 E EC A31
1.65 Mb
BIM/CAD models
MPA 1000-4000 E/W EC A31
1.76 Mb
Image
MPA 300 E-1.7 EC A31 - image 1
585 Kb
D H L L1 L2 W W1 W2
160 290 850 903 950 400 514 313
Other accessories
Name Photo Description
Vents SF 334x226x48 G4 SF 334x226x48 G4 Panel filter G4
Vents SF 334x226x48 F7 SF 334x226x48 F7 F7 panel filter
Other accessories
Name Photo Description
Vents VVG 125 VVG 125 Flexible anti-vibration connector
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Vents Belimo TF24 Belimo TF24 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions