VENTS MPA 3200 E3

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional diagrams
  • Legend
Description
Description
DESCRIPTION
  • Air supply MPA unit is a complete ventilation unit for air filtration, air heating and supply to premises. 

  • Compatible with 400х200, 500х250, 500х300, 600х300, 600х350 mm rectangular air ducts.
CASING
  • Steel casing covered with aluzinc coating internally filled with 25 mm heat- and sound-insulating layer made of mineral wool.

FILTER
  • Integrated panel G4 filter ensures sufficient supply air purification.

HEATER
  • Both electric heater are used for heating of supply air in cold season. 

  • Tubular heating elements of the electric fan heater are ribbed to increase the heat exchange surface area and heat transfer to supply air.
FAN
  • Centrifugal double-inlet fan with forward curved blades and built-in overheating protection with automatic restart.

  • The fan motor and impeller are dynamically balanced in two planes.

  • The ball bearings in the electric motor are maintenance free and designed for at least 40000 hours operation.

Control and automation
 
  • Two options for supply unit modifications are possible:
    • No control. Customer-defined and customer-selected automation system.
    • Integrated control and automation system for three-speed (air capacity) control and setting supply air temperature. The unit may be controlled from the external control panel fixed on 10 m wire delivered as a standard.
MPA E control and protection functions
 
  • switching the unit on/off from the control panel;
  • setting the supply air temperature from the remote control panel and maintaining it by the triac heater control;
  • fan speed control from the control panel;
  • tracking the set operating control logic while turning the unit on and off;
  • unit operation according to daily and week schedule;
  • overheating protection of the electric heating elements;
  • disabling electric heater operation when the fans are not running;
  • electric heater overheating protection by two overheating thermostats, one thermostat activated at 60 °C with automatic reset and another thermostat activated at 90 °C with automatic reset;
  • actuating the air damper;
  • input for alarm fire fighting signal;
  • input from external humidity sensor, CO2 sensor, etc (normally opened dry contact). On sensor’s output signal the unit switches to the maximum speed.
MOUNTING  
  • The supply unit can be mounted on the floor, suspended to the ceiling by means of a seat angle with a flexible connector or fixed to the wall using brackets.

  • The unit can be installed either in such service spaces as balcony, storeroom, basement, roof space or in main premises above the suspended ceiling, in the pocket or placed directly in the room.

  • The unit can be mounted in any position but the vertical one with air downstream because the heating elements are not allowed under the fan.

  • Access for the unit maintenance and filter cleaning shall be provided.

Accessories to supply units:
 
Type Replaceable filter Filter type
MPА 800 Е1 SF MPA 800/1200 G4 panel filter
MPА 1200 Е3
MPА 1800 Е3 SF MPA 1800/2500 G4 panel filter
MPА 2500 Е3
MPА 3200 Е3 SF MPA 3200/3500 G4 panel filter
MPА 3500 Е3

OFFICE VENTILATION EXAMPLE

 
  • Air supply and exhaust ventilation in modern office can be arranged as follows. Air handing MPA unit, exhaust fan complying with MPA unit characteristics, intake and exhaust main air ducts are mounted in the hall behind the suspended ceiling. The branchings are laid into the office premises and air distribution units. 

  • Fresh air is extracted from outside through the external grille, filtered in the air handling unit, heated to the required temperature and supplied to the office rooms through the branch duct system. Exhaust air is extracted outside through the external grille by means of the exhaust fan. Thus the office has the permanent fresh air supply, controllable air exchange, no draughts when opened windows, no dust and no noise
VENTS MPA unit office air exchange example
Characteristics
Characteristics
Parameter MPA 3200 E3
Measurement unit
Frequency 50 Hz
Engine Type 380В / 50Гц -
Phase 3 ˜
Voltage 400 Y V
Maximum fan power Maximum fan power W
Electric heater power Electric heater power W
Electric heater current Electric heater current 36.4 A
Air capacity 3200 m³/h
Total unit power 26470 W
Total unit current 38.7 A
Maximum air capacity 3200 m³/h
Fan current Fan current A
RPM 1200 min-1
Noize level at 3 m dBА
Casing material aluzinc -
Maximum transported air temperature Maximum transported air temperature °С
Insulation 25 mm, mineral wool -
Heating electric heating -
Filter G4 -
Connected air duct diameter 600х300 mm
Width 600 mm
Mass 69.4 kg
Height 300 mm
Heater type Heater type electric -
Duct for rectangular air ducts -
Type Type приточная -
Files archieve
Downloads
Name
Brochure "VENTS MPA E, MPA W" (pdf 1.13Mb)
Download high quality image "VENTS MPA...E (ErP 2016, 2018)" (psd 4.08Mb)
User's manual "VENTS MPA 3200-3500 E" (pdf 4.48Mb)
User's manual "VENTS MPA 800-2500 E" (pdf 8.77Mb)
Certificate GS "MPA (230V)" (pdf 180.41Kb)
Certificate GS "MPА (3-400V)" (pdf 183.89Kb)
Declaration of сonformity "MPA" (pdf 1.55Mb)
User's manual "VENTS MPA E" (pdf 4.08Mb)
Certificate LVD "MPA (230V)" (pdf 227.41Kb)
Certificate LVD "MPА (3-400V)" (pdf 227.69Kb)
Download image "VENTS MPA...E (ErP 2016, 2018)" for your website (png 383.66Kb)
User's manual “Control Panel SYNERGY А16” (pdf 2.29Mb)
Dimensions
Characteristics
VENTS MPA 3200 E3
Parameter Value Measurement unit
B2 759 mm
B3 710 mm
H1 320 mm
H2 530 mm
L 1000 mm
L2 440 mm
Additional diagrams
Additional diagrams
Sound-power level   Octave-frequency band [Hz]
  Hz   General   63   125   250   500   1000   2000   4000   8000
LwA to inlet   dBA 82 85 84 83 76 77 73 73 68
LwA to outlet dBA 86 83 83 83 82 80 72 73 70
LwA to environment dBA 63 68 64 67 55 55 52 45 45

Legend
Legend
Series   Rated air flow, m3/h    Phase   Heater type   Integrated control system
VENTS MPA
  800, 1200, 1800, 2500, 3200, 3500   1 - single phase;
3 - three phases
  E - electric   _ - no control system
LCD - integrated automation with A8 control panel
Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
Basic parameter for domestic fan selection