Unit of measurement | MPA 400 E-3.3 EC A31 | |
Connected air duct size | mm | 200 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50 |
Rated power | W | 62 |
Power of electrical reheater | W | 3300 |
Unit current | A | 5.4 |
Maximum airflow | m3/h | 430 |
Sound pressure level LpA at 3 m | dB(A) | 31 |
Weight | kg | 25 |
Filter | - | Coarse 90%/G4 (опція ePM1 70%/F7) |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -30 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | MPA 400 E-3.3 EC A31 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
54 | A+ | 26.9 | B | 11.4 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 310 | |||||
Electric power input (W) | 62 | |||||
Reference flow rate (m3/s) | 0.061 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.105 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 36 | |||||
Declared typology | RVU UVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
55 | 55 | 55 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Vents SF 334x287x48 G4 | Panel filter G4 | |
Vents SF 334x287x48 F7 | F7 panel filter |
Name | Photo | Description |
---|---|---|
Vents VVG 200 | Flexible anti-vibration connector |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 200/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KRV 200 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions | |
Vents Belimo TF24 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |