Vents PA 01 E LCD

Suspended air supply units in the sound- and heat-insulated casing with the water or electric heater
  • Power of electrical reheater: 12000 W
  • Maximum airflow: 1275 m3/h
  • Sound pressure level LpA at 3 m: 51 dB(A)
  • Filter: G4
  • Sound insulation
  • Motor type: AC
  • Reheater: Electric
  • Control: Remote Control
  • Casing material: Galvanized steel
Unit of measurement PA 01 E LCD
Connected air duct size mm 400x200
Minimum supply voltage V 400
Maximum supply voltage V 400
Power supply frequency Hz 50
Rated power W 320
Power of electrical reheater W 12000
Unit current A 18
Maximum airflow m3/h 1275
Sound pressure level LpA at 3 m dB(A) 51
Weight kg 56
Filter - G4
Transported air temperature (max) °С 55
Transported air temperature (min) °С -25
Ambient air temperature min °С -25
Ambient air temperature max °С 55
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS PA...E, PA...W" product description 01-2023
5.33 Mb
Manual
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03)
7.49 Mb
Manual
"VENTS PA...E. Unit without automation block" user's manual 06-2012 (V53EN-02)
584 Kb
Manual
"VENTS PA...W. Unit without automation block" user's manual 09-2019 (V43EN-03)
1.51 Mb
Manual
"Control and automation block for VENTS PA...W" user's manual 06-2018 (V43(automatic)EN-06)
1.68 Mb
Image
PA 01 E LCD - image 1
410 Kb
Vents PA 01 E LCD - Dimensions
B B1 B2 B3 H H1 H2 L L1
400 420 624 582 200 220 374 1145 1106
Name Photo Description
Vents SR 400x200 SR 400x200 The plate silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents OKW 400x200-3 OKW 400x200-3 Duct water coil air coolers are designed for cooling of supply air in rectangular ventilation systems and can be applied in supply or supply and exhaust ventilation systems
Name Photo Description
Vents RRV 400x200 RRV 400x200 Air flow controllers
Name Photo Description
Vents VVG 400x200 VVG 400x200 Flexible anti-vibration connector
Name Photo Description
Vents SKRA 400x200/24 SKRA 400x200/24 The mixing chambers is designed for mixing (recirculation) of extract and intake air in a required ratio
Name Photo Description
Vents OKF 400x200-3 OKF 400x200-3 Direct-expansion duct coolers are designed for cooling of supply air in rectangular ventilation systems and can be used either for supply or supply and exhaust units
Other accessories
Name Photo Description
Vents SF 475x270x48 G4 SF 475x270x48 G4 Panel filter G4