Unit of measurement | Stream 100/125 | |||
Connected air duct size | mm | 125 | ||
Speed | - | 1 | 2 | 3 |
Phases | - | 1 | ||
Minimum supply voltage | V | 230 | ||
Maximum supply voltage | V | 230 | ||
Power supply frequency | Hz | 50/60 | ||
Rated power | W | 9 | 13 | 21 |
Unit current | A | 0.81 | 0.09 | 0.1 |
Maximum airflow | m3/h | 173 | 240 | 320 |
rotation speed at 50hz | - | 2252 | 2662 | 2810 |
Sound pressure level LpA at 3 m | dB(A) | 16 | 21 | 25 |
Weight | kg | 3.6 | ||
Transported air temperature (max) | °С | 55 | ||
Transported air temperature (min) | °С | -25 | ||
Ambient air temperature min | °С | 1 | ||
Ambient air temperature max | °С | 40 | ||
Ingress protection rating | - | IPX4 | ||
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | Stream 100/125 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-54 | A+ | -26.9 | B | -11.4 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 320 | |||||
Electric power input (W) | 34 | |||||
Reference flow rate (m3/s) | 0.062 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.106 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 28 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
56 | 56 | 56 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Vents SR 125/600 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Vents SR 125/900 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Vents SR 125/1200 |
![]() |
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
Name | Photo | Description |
---|---|---|
Vents FB 125 |
![]() |
Round panel air filters |
Vents FBK 125-4 |
![]() |
Round bag air filters |
Vents FBK 125-5 |
![]() |
Round bag air filters |
Vents FBK 125-7 |
![]() |
Round bag air filters |
Name | Photo | Description |
---|---|---|
Vents NK 125-0,6-1 |
![]() |
Round electric inline heaters with round cross-section |
Vents NK 125-0,8-1 |
![]() |
Round electric inline heaters with round cross-section |
Vents NK 125-1,2-1 |
![]() |
Round electric inline heaters with round cross-section |
Vents NK 125-1,6-1 |
![]() |
Round electric inline heaters with round cross-section |
Vents NK 125-2,4-1 |
![]() |
Round electric inline heaters with round cross-section |
Name | Photo | Description |
---|---|---|
Vents NKV 125-2 |
![]() |
Inline water supply air heaters or heater for air handling units with a round cross-section |
Vents NKV 125-4 |
![]() |
Inline water supply air heaters or heater for air handling units with a round cross-section |
Name | Photo | Description |
---|---|---|
Vents KOM 125 |
![]() |
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
Vents KR 125 |
![]() |
Air dampers for controlling air flow in round air ducts |
Name | Photo | Description |
---|---|---|
Vents P3-1-300 |
![]() |
Switch |
Name | Photo | Description |
---|---|---|
Vents RS-0,5-PS |
![]() |
Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control |
Vents RS-3,0-T |
![]() |
Applied in ventilation systems for speed switching ON/OFF and speed control of single-phase power-controlled motors |
Vents RS-1-400 |
![]() |
Speed controller |