Unit of measurement | Stream 100/125 (125 spigot) R | |||
Connected air duct size | mm | 125 | ||
Speed | - | 1 | 2 | 3 |
Phases | - | 1 | ||
Minimum supply voltage | V | 230 | ||
Maximum supply voltage | V | 230 | ||
Power supply frequency | Hz | 50 | ||
Rated power | W | 31 | 33 | 34 |
Unit current | A | 0.14 | 0.14 | 0.16 |
Maximum airflow | m3/h | 164 | 216 | 320 |
rotation speed at 50hz | - | 1552 | 1952 | 2356 |
Sound pressure level LpA at 3 m | dB(A) | 20 | 22 | 28 |
Weight | kg | 5 | ||
Transported air temperature (max) | °С | 55 | ||
Transported air temperature (min) | °С | -25 | ||
Ingress protection rating | - | IPX4 | ||
Ingress protection rating of the drive | - | IP20 |
Trademark | Vents | |||||
Model | Stream 100/125 (125 spigot) R | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
54 | A+ | 26.9 | B | 11.4 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 320 | |||||
Electric power input (W) | 34 | |||||
Reference flow rate (m3/s) | 0.062 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.106 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 28 | |||||
Declared typology | RVU UVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
56 | 56 | 56 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Vents SR 125/600 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 125/900 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 125/1200 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents FB 125 |
![]() |
Panel filters |
Vents FBK 125-4 |
![]() |
Pocket filter |
Vents FBK 125-5 |
![]() |
Pocket filter |
Vents FBK 125-7 |
![]() |
Pocket filter |
Name | Photo | Description |
---|---|---|
Vents NK 125-0,6-1 |
![]() |
Duct electric heater |
Vents NK 125-0,8-1 |
![]() |
Duct electric heater |
Vents NK 125-1,2-1 |
![]() |
Duct electric heater |
Vents NK 125-1,6-1 |
![]() |
Duct electric heater |
Vents NK 125-2,4-1 |
![]() |
Duct electric heater |
Name | Photo | Description |
---|---|---|
Vents NKV 125-2 |
![]() |
Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Vents NKV 125-4 |
![]() |
Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Name | Photo | Description |
---|---|---|
Vents KOM 125 |
![]() |
Spring-loaded backdraft damper for round ducts |
Vents KR 125 |
![]() |
Air damper for air flow control in round air ducts |
Name | Photo | Description |
---|---|---|
Vents RTSD-1-400 |
![]() |
Temperature regulator |
Name | Photo | Description |
---|---|---|
Vents P3-1-300 |
![]() |
Switch |
Name | Photo | Description |
---|---|---|
Vents T-1,5 N |
![]() |
Sensor |