Unit of measurement | Stream 100/125 EC S (100 spigot) | |
Connected air duct size | mm | 100 |
Phases | - | 1 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 39 |
Unit current | A | 0.36 |
Maximum airflow | m3/h | 295 |
rotation speed at 50hz | - | 3168 |
Sound pressure level LpA at 3 m | dB(A) | 31 |
Weight | kg | 5 |
Transported air temperature (max) | °С | 55 |
Transported air temperature (min) | °С | -25 |
Ingress protection rating | - | IPX4 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | Stream 100/125 EC S (100 spigot) | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
54.3 | A+ | 27.3 | B | 11.8 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 320 | |||||
Electric power input (W) | 39 | |||||
Reference flow rate (m3/s) | 0.054 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.077 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 54 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
41 | 41 | 41 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |
Name | Photo | Description |
---|---|---|
Vents NKV 100-2 |
![]() |
Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Vents NKV 100-4 |
![]() |
Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units |
Name | Photo | Description |
---|---|---|
Vents NK 100-1,8-1 |
![]() |
Duct electric heater |
Vents NK 100-1,6-1 |
![]() |
Duct electric heater |
Vents NK 100-1,2-1 |
![]() |
Duct electric heater |
Vents NK 100-0,8-1 |
![]() |
Duct electric heater |
Vents NK 100-0,6-1 |
![]() |
Duct electric heater |
Vents NK 100-0,6-1 U |
![]() |
Duct electric heater with temperature controller or control unit |
Vents NK 100-0,8-1 U |
![]() |
Duct electric heater with temperature controller or control unit |
Vents NK 100-1,2-1 U |
![]() |
Duct electric heater with temperature controller or control unit |
Vents NK 100-1,6-1 U |
![]() |
Duct electric heater with temperature controller or control unit |
Vents NK 100-1,8-1 U |
![]() |
Duct electric heater with temperature controller or control unit |
Name | Photo | Description |
---|---|---|
Vents FBK 100-7 |
![]() |
Pocket filter |
Vents FBK 100-5 |
![]() |
Pocket filter |
Vents FBK 100-4 |
![]() |
Pocket filter |
Vents FB 100 |
![]() |
Panel filters |
Name | Photo | Description |
---|---|---|
Vents R-1/010 |
![]() |
Speed controller for EC motors |
Name | Photo | Description |
---|---|---|
Vents KR 100 |
![]() |
Air damper for air flow control in round air ducts |
Vents KOM 100 |
![]() |
Spring-loaded backdraft damper for round ducts |
Vents KOMu 100 |
![]() |
Spring-loaded backdraft damper for round ducts |
Name | Photo | Description |
---|---|---|
Vents SR 100/1200 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 100/900 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 100/600 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |