Vents TT 125 TV

Mixed-flow inline fans
  • Sound pressure level LpA at 3 m: 37 dB(A)
  • Motor type: AC
  • Control: Built-in speed controller
  • Impeller type: Mixed-flow
  • Casing material: Plastic
  • Installation in any position
  • Timer: Turn off timer
Unit of measurement TT 125 TV
Connected air duct size mm 125
Speed - 1 2
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 23 37
Unit current A 0.18 0.27
Maximum airflow m3/h 220 280
Sound pressure level LpA at 3 m dB(A) 28 37
Weight kg 1.79
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ingress protection rating - IPX4
Ingress protection rating of the drive - IPX4
Vents TT 125 TV 0 0 2016
Trademark Vents
Model TT 125 TV
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
0 A+ 0 C 0 F
Type of ventilation unit Unidirectional
Type of drive installed Variable speed
Type of heat recovery system None
Maximum flow rate (m3/h) 0
Electric power input (W) 0
Reference flow rate (m3/s) 0
Specific power input (SPI) (W/(m3/h)) 0
Control typology Local demand control
Maximum external leakage rates (%) 0
Sound power level (dB(A)) 0
Declared typology RVU UVU
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
0 0 0
The annual heating saved (AHS) (kWh/a) Cold Average Warm
0 0 0
Datasheet
"VENTS TT" product description 08-2025
1.46 Mb
Manual
"VENTS TT" user's manual 10-2022 (V10EN-12)
959 Kb
Image
TT 125 TV - image 1
397 Kb
∅D B H L
123 167 190 246