| Unit of measurement | TT PRO 160 EC | |
| Connected air duct size | mm | 160 |
| Phases | - | 1 |
| Minimum supply voltage | V | 230 |
| Maximum supply voltage | V | 230 |
| Power supply frequency | Hz | 50/60 |
| Rated power | W | 55 |
| Unit current | A | 0.48 |
| Maximum airflow | m³/h | 600 |
| Rotation speed at 50hz | - | 3390 |
| Sound pressure level LpA at 3 m | dB(A) | 46 |
| Weight | kg | 3.25 |
| Transported air temperature (max) | °С | 55 |
| Transported air temperature (min) | °С | -25 |
| Ingress protection rating | - | IPX4 |
| Impeller material | - | Plastic |
| Trademark | Vents | |||||
| Model | TT PRO 160 EC | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -54.6 | A+ | -27.5 | B | -12 | E | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 508 | |||||
| Electric power input (W) | 54.3 | |||||
| Reference flow rate (m³/s) | 0.099 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.058 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 66 | |||||
| Declared typology | RVU UVU | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 31 | 31 | 31 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents SR 160/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SRF 160/2000 |
|
Silencers made of aluminium alloy filled with non-combustible sound-absorbing material |
| Vents SRP 160/500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/600 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/750 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/900 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/1200 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/1500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 160/2000 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Name | Photo | Description |
|---|---|---|
| Vents FB K2 160 G4/F8 UV |
|
Filter boxes with a high purification level and air disinfection |
| Vents FB K2 160 G4/C/F8 UV |
|
Filter boxes with a high purification level and air disinfection |
| Vents FB K2 160 G4/H13 UV |
|
Filter boxes with a high purification level and air disinfection |
| Vents FB K2 160 G4/C/H13 UV |
|
Filter boxes with a high purification level and air disinfection |
| Vents FB K2 160 UV |
|
Filter boxes with a high purification level and air disinfection |
| Vents FB 160 |
|
Round panel air filters |
| Vents FBV 160 |
|
Round panel air filters with a large filtration area |
| Vents FBK 160-4 |
|
Round bag air filters |
| Vents FBK 160-5 |
|
Round bag air filters |
| Vents FBK 160-7 |
|
Round bag air filters |
| Name | Photo | Description |
|---|---|---|
| Vents KOM 160 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOM1 160 |
|
Backdraught gravity damper for shutting off air flow in round air ducts |
| Vents KR 160 |
|
Air dampers for controlling air flow in round air ducts |
| Vents KRV 160 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents VVG 160 |
|
Flexible anti-vibration inserts for round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents NKV 160-2 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Name | Photo | Description |
|---|---|---|
| Vents NK 160-1,2-1 |
|
Round electric inline heaters with round cross-section |