Unit of measurement | TT Silent-M 200 T | |||
Connected air duct size | mm | 200 | ||
Speed | - | 1 | 2 | 3 |
Minimum supply voltage | V | 230 | ||
Maximum supply voltage | V | 230 | ||
Power supply frequency | Hz | 50/60 | ||
Rated power | W | 82 | 100 | 110 |
Unit current | A | 0.37 | 0.44 | 0.49 |
Maximum airflow | m3/h | 731 | 961 | 1020 |
Sound pressure level LpA at 3 m | dB(A) | 30 | 34 | 36 |
Weight | kg | 8 | ||
Transported air temperature (max) | °С | 60 | ||
Ingress protection rating | - | IPX4 | ||
Ingress protection rating of the drive | - | IPX4 |
Trademark | Vents | |||||
Model | TT Silent-M 200 T | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-32.6 | B | -14.6 | E | -4.4 | F | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Multi-speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 800 | |||||
Electric power input (W) | 110 | |||||
Reference flow rate (m3/s) | 0.156 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.139 | |||||
Control typology | Clock control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 33 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
164 | 164 | 164 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
3667 | 1874 | 848 |