VENTS PA 04 W3

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The PA unit is a ready to use ventilation unit for air filtration, warming and supply to the room.

CASING
  • Steel casing covered with aluzinc coating internally filled with 50 mm heat- and sound-insulating layer made of mineral wool.

FILTER
  • Integrated panel G4 filter ensures sufficient supply air purification (optionally F7).

HEATER
  • The PA units are equipped with electric (PA…E model) or water (PA…W model) heater. 

  • Depending on the required heating capacity the water heaters are available in two-, three- or four-row modifications.

  • The water heaters are designed for max. operating pressure 1.0 MPa (10 bar) and max. operating temperature 95 °C of the heat medium.

FAN
  • The unit is equipped with a direct-driven centrifugal fan with backward curved blades and external rotor motor.

  • The fan configuration ensures the best operating characteristics: high air capacity and efficiency combined with low noise level.

MOUNTING  
  • The unit is designed for indoor installation either on the floor, on the wall or under the ceiling by means of a seat angle with inserted vibration-damping element or attached to a wall with brackets.

  • The unit can be mounted either in service spaces or in main premises above the suspended ceiling, in the pocket or the unit can be placed directly in the room.

  • All the electrical connections are performed through the terminal box placed in the connection box.

  • PA supply units are supplied with the fastening brackets to facilitate mounting.

  • The unit can be mounted in any position but the vertical one with vertical air downstream because the electrical heating elements are not allowed under the fan.
  • Access for the unit maintenance and filter cleaning shall be provided.

  • The unit design enables to lead the water heater pipes to the right or to the left while mounting. The pipes are directed on the right on supply air side by default.

CONTROL AND AUTOMATION  
  • The supply units are available in two modifications:
    • No control system. Customer-defined and customer-selected automation system.
    • Integrated control and automation system for speed (air capacity) control and setting supply air temperature. The unit may be remotely controlled from the external control panel fixed on wire.
PA…W control and protection functions
 
  • control from the control panel: switching the unit on/off, fan speed selection (low/medium/high speed), selecting heating/cooling modes (if connected to duct cooler);
  • maintaining supply air temperature set from the control panel by controlling the circulation pump and actuating the heat medium regulating valve; input from the heat medium flow switch (pump alarm);
  • safe start-up/ shutdown of the fans, warming up of the water heater before start-up; return heat medium temperature control when the fan is off;
  • freezing protection of the water heating coils by the exhaust temperature sensor and the return heat medium temperature sensor;
  • control of the compressor and condensing unit of the water cooler by the room temperature sensor (for the models equipped with a duct air cooler);
  • filter clogging degree with differential pressure sensor;
  • actuating the external air damper with a return spring;
  • unit shut down at signal from the fire alarm system.
SUPPLEMENTARY EQUIPMENT  
  • The mixing units USWK are recommended for smooth supply air temperature regulation in the units equipped with water heaters.
  • The mixing unit USWK with three-way heat medium regulating valve and circulation pump provides smooth heating capacity regulation and minimizes the water heater freezing danger.
  • To disable uncontrollable air flow when the fan is off it is recommended to install the air damper with servo actuator from outside at the unit inlet.
  • To protect the water heater against cold intake air in case of power failure for the units with water heaters it is recommended to install the air damper with a return spring.
  • For attenuation of sound generated by the fan it is recommended to install the duct silencer (refer SR).
  • For vibration absorbing it is recommended to install the flexible anti-vibration connectors (refer VVG) on both sides of the unit.
Characteristics
Characteristics
Parameter PA 04 W3
Measurement unit
Heating water heating -
Frequency 50 Hz
Phase 3 ˜
Voltage 400 V
Fan current 4.3 A
Maximum fan power 2300 W
Sound pressure level at 3 m distance 75 dBА
Air capacity 4100 m³/h
Maximum air capacity 4100 m³/h
Total unit power 2300 W
Total unit current 4.3 A
RPM 2840 min-1
Filter G4 (F7) pocket type* -
Transported air temperature -25 ... +70 °С
Casing material aluzinc -
Insulation 50 mm mineral wool -
Width 700 mm
Connected air duct diameter 700х400 mm
Number of water (glycol) coil rows 3 -
Mass 110 kg
Height 400 mm
Number of rows in water heater Number of rows in water heater 3-трехрядный -
Form-ducts for rectangular air ducts -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
Brochure "VENTS PA...E, PA...W" (pdf 5.07Mb)
Download high quality image "VENTS PA...W (ErP 2016, 2018)" (psd 4.09Mb)
User's manual "VENTS PA...W. Unit without automation block" (pdf 1.44Mb)
User's manual "Control and automation block for VENTS PA...W" (pdf 1.61Mb)
User's manual "Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" (pdf 1.38Mb)
Download image "VENTS PA...W (ErP 2016, 2018)" for your website (png 367.25Kb)
Dimensions
Characteristics
VENTS PA 04 W3
Parameter Value Measurement unit
B 700 mm
B3 844 mm
B1 720 mm
L 1302 mm
H 400 mm
L1 1262 mm
H2 546 mm
B2 888 mm
H1 420 mm
Additional characteristics
Additional characteristics
Sound-power level Gen Octave-frequency band [Hz]
63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 108 83 106 99 99 96 96 93 75
LWA to outlet dBA 118 82 115 112 105 105 99 97 84
LWA to environment dBA 95 61 93 92 76 67 65 71 68
Designation key
Designation key
Series Unit standard size Heater type Row number of the heater  Integrated control system
VENTS PA  01; 02; 03; 04 W: water 2: two rows;
3: three rows;
4: four rows
_: no control system
LCD: integrated automation with A16 (PA..E) or A13 (PA..W) control panel
Accessories
Accessories
Type G4 replaceable filter F F7 replaceable filter Filter type
PA 01 W2 SFK 474x269x27 G4 SFK 474x269x27 F7 pocket filter
PA 01 W4
PA 02 W2 SFK 538x342x27 G4 SFK 474x269x27 F7 pocket filter
PA 02 W4
PA 03 W2 SFK 637x395x27 G4 SFK 637x395x27 F7 pocket filter
PA 03 W4
PA 04 W2 SFK 737x441x27 G4 SFK 737x441x27 F7 pocket filter
PA 04 W3