VENTS VUT 300 HB EC A21

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION MODIFICATIONS
  • The VUT/VUE HB EC and VUT/VUE HBE EC air handling units are the fully-featured ventilation units that ensure air filtration, fresh air supply and stale air extract.
  • At the same time, the heat of the extract air is transferred to the supply air due to the high-efficiency counter-flow plate heat exchanger.
  • The units are applied as components of ventilation and air conditioning networks for various premises.
  • Due to high-efficient EC motors and expanded counter-flow heat exchanger surface the energy saving parameters of the units are the best at the market.
  • Designed for connection to ø160, 200 and 250 mm round air ducts.
  • The VUT HB EC model is equipped with a counter-flow heat exchanger made of polystyrene, a bypass and EC motors.
  • The VUT HBE EC model is equipped with a counter-flow heat exchanger made of polystyrene, a bypass, EC motors and an electric heater.
  • The VUE HB EC model is equipped with a counter-flow heat exchanger made of enthalpy, a bypass and EC motors.
  • The VUE HBE EC model is equipped with a counter-flow heat exchanger made of enthalpy, a bypass, EC motors and an electric heater.
CASING
  • Made of aluzinc steel, internally filled with a 40 mm mineral wool heat- and sound-insulating layer.
FANS FILTER
  • High-efficient electronically-commutated motors with external rotor.
  • These state-of-the-art motors are the most advanced solution in energy efficiency today.
  • EC motors are characterised with high performance and optimum control across the entire speed range.
  • In addition to that, the efficiency of the electronically commutated motor reaches very impressive levels of up to 90 %.
  • The unit sizes 300 and 400 are equipped with fans with forward curved blades.
  • These fans provide constant set air flow even in case of variable air resistance in the ventilation system, i.e. in case of clogged filters.
  • The 700 size units are equipped with fans with backward curved blades.
  • Two built-in panel filters with filtration class G4 and F7 provide efficient supply air filtration. The G4 panel filter is used for extract air cleaning.

HEAT EXCHANGER  
  • The VUT units are equipped with a counter-flow polystyrene heat exchanger.
  • In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses.
  • This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
  • In the warm season the ambient air heat is transferred to the exhaust air stream.
  • This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.
  • The VUE units are equipped with a counter-flow heat exchanger with an enthalpy at the core
  • In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy reducing the heat losses from ventilation.
  • The ambient air heat and moisture are transferred to the exhaust air stream through the enthalpy in the warm season.
  • This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.
HEATER  
  • The VUT/VUE HBE EC units are equipped with an electric heater for additional heating of supply air downstream of the heat exchanger.
  • The VUT/VUE HB EC A21 units are not equipped with a built-in electric heater. It is available upon separate order and may be integrated into the unit. 
BYPASS  
  • The unit is equipped with a bypass which is automatically opened in summer if there is a need to cool down the ventilated area with cool intake air. 
  • If the unit is equipped with an electric heater, the bypass is used for freeze protection of the heat exchanger.
  • If the unit is not equipped with an electric heater, in case of freezing danger according to the temperature sensor readings the supply fan is stopped and warm extract air warms up the heat exchanger.
  • After the heat exchanger defrosting and when the freezing danger is no longer imminent, the supply fan is restarted and the unit reverts to the standard operation mode.
AUTOMATION  
  • The VUT/VUE HB(E) EC A21 units are equipped with an integrated control system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • The remote control panel is not included in the delivery set (purchased separately).
  • To control the unit using a mobile application via Wi-Fi, you need to download the VENTS AHU mobile application.
  • The VUT/VUE HB(E) EC A14 units have an integrated control system with a wall-mounted control panel A14 with a LED indication.

FREEZE PROTECTION  
  • In the VUT/VUE HB EC A14 units, freeze protection is based on cyclic stops of the supply fan, while the warm extract air warms the heat exchanger. Then the supply fan is turned on and the unit reverts to normal operation.
  • Freeze protection in the VUT/VUE HBE EC A21 units is achieved by a bypass.
  • A preheater can be additionally installed in the VUT/VUE HB EC A21 units for freeze protection.
CONTROL AND AUTOMATION  
Functions A21 A14
Control via Wi-Fi using a mobile application + -
Control via a wired remote control panel option (A22)
А14
Wired remote LCD control panel option (А25)
-
Control via a wireless remote control panel option (A22 Wi-Fi)
-
BMS RS-485
WI-FI
Ethernet
MODBUS (RTU, TCP)
-
Service Vents Cloud Server + -
Speed selection + +
Filter replacement indication according to hour meter readings according to hour meter readings
according to filter clogging differential pressure switch readings -
Alarm indication full alarm description in the mobile application LED alarm indication
Week-scheduled operation + -
Bypass automatic -
manual manual
Timers + -
Boost mode + -
Kamin mode + -
Freeze protection through cyclic stops of the supply fan through cyclic stops of the supply fan
through preheating (option) -
using a bypass -
Reheater connection option -
Cooler connection option -
Minimum supply air temperature control + -
Humidity control option option
CO2 controller option option
VOC controller option -
PM2.5 control option -
Fire alarm sensor connection option option
*Option. The functionality is available when you purchase the appropriate accessory.
MOUNTING  
  • The unit is designed for suspended or floor mounting.
  • Access for service and filter cleaning from the front panel.
  • During mounting stage the front and the back panels can be reversed providing either left-handed or right-handed unit mounting.
UNIT DESIGN  
APPLICATION OPTIONS  
   
Characteristics
Characteristics
Parameter VUT 300 HB EC A21
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Electric heater power - W
Max. unit current without electric heater 1.4 A
Sound pressure level at 3 m distance 24 dBА
Air capacity 380 m³/h
Electric heater current Electric heater current - A
Maximum unit power with an electric heater 182 W
Maximum unit current (with an electric heater) 1.4 A
RPM 2100 min-1
Max. unit power without electric heater 182 W
Heat recovery efficiency 80-98 %
Transported air temperature -25 ... +40 °С
Casing material galvanized steel -
Insulation 40 mm mineral wool -
Filter: extract G4 -
Filter: supply * option G4, F7 -
Connected air duct diameter 160 mm
Mass 63.1 kg
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC Class A+ -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
Brochure "VENTS VUT/VUE HB/HBE EC" (pdf 1.61Mb)
Download image "VENTS VUT/VUE HB/HBE EC (ErP 2016, 2018)" for your website (png 445.43Kb)
Download high quality image "VENTS VUT/VUE HB/HBE EC (ErP 2016, 2018)" (psd 2.03Mb)
User's manual "VENTS VUT/VUE HB/HBE EC" (pdf 4.25Mb)
Dimensions
Characteristics
VENTS VUT 300 HB EC A21
Parameter Value Measurement unit
∅D 157 mm
B 568 mm
B1 190 mm
B2 189 mm
H 479 mm
H1 193 mm
H2 118 mm
L 1083 mm
L1 1180 mm
Additional characteristics
Additional characteristics
A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000    
LWA to supply air inlet dBA 67 50 55 56 62 60 62 56 50    
LWA to supply air outlet dBA 53 42 47 46 46 44 39 29 21    
LWA to exhaust air inlet dBA 68 56 54 61 62 59 61 56 50    
LWA to exhaust air outlet dBA 55 42 47 51 48 46 43 31 22    
LWA surrounding dBA 45 34 35 40 39 32 36 31 27 24 34
Designation key
Designation key
Series Rated air flow [m3/h] Spigot orientation Bypass Heater type Motor type Automation
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
300; 400; 700 H: horizontal B: bypass

_: without a heater
E: electric heater

EC: synchronous
electronically
commutated motor

А14
А21
Accessories
Accessories
Model G4 panel filter F7 panel filter LCD control pane Control pane Wi-Fi controllable control Humidity sensor (0-10 V) CO2 sensor CO2 sensor with indication Humidity sensor VOC sensor (0-10 V) CO2 sensor (0-10 V) Humidity sensor (0-10 V)
               
VUT/VUE 300 HB EC A21 SF 484x178x48
G4
SF 484x178x48
F7
А25 А22 А22 Wi-Fi HV2 CO2-1  CO2-2 HR-S DPWQ30600 DPWQ40200 DPWС11200
VUT/VUE 300 HBE EC A21
VUT/VUE 300 HB EC A14 - - - - - -
VUT/VUE 400 HB EC A21 SF 600х205х48
G4
SF 600х205х48
F7
А25 А22 А22 Wi-Fi  DPWQ30600 DPWQ40200 DPWС11200
VUT/VUE 400 HBE EC A21
VUT/VUE 400 HB EC A14 - - - - - -
VUT/VUE 700 HB EC A21 SF 784х253х48
G4
SF 784х253х48
F7
А25 А22 А22 Wi-Fi DPWQ30600 DPWQ40200 DPWС11200
VUT/VUE 700 HBE EC A21
VUT/VUE 700 HB EC A14 - - - - - -

 

Model Electric reheater Electric heater for preheating Silencers Back valves Air dampers Clamps Drain pump Electric actuator
                   
VUT/VUE 300 HB EC A21 NKD 160 NKP 160 SR 160 600/900/1200 SRF 160 600/900/1200 KOM 160 KRV 160 C 160 DN-2 LF230 TF230
VUT/VUE 300 HBE EC A21 - NKP 160
VUT/VUE 300 HB EC A14 -
VUT/VUE 400 HB EC A21 NKD 200 NKP 200 SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KRV 200  C 200 
VUT/VUE 400 HBE EC A21 - NKP 200
VUT/VUE 400 HB EC A14 - -
VUT/VUE 700 HB EC A21 NKD 250 NKP 250 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KRV 250 C 250
VUT/VUE 700 HBE EC A21 - NKP 250
VUT/VUE 700 HB EC A14 - -
Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
How often do you use equipment selection program?