Vents VPA 150-2,4-1 LCD

Vents VPA 150-2,4-1 LCD - Supply units in the compact sound- and heat-insulated casing with electric heater
Out of production
Supply units in the compact sound- and heat-insulated casing with electric heater
  • Power of electrical reheater: 2400 W
  • Maximum airflow: 425 m3/h
  • Sound pressure level LpA at 3 m: 29 dB(A)
  • Filter: G4
  • Sound insulation
  • Motor type: AC
  • Reheater: Electric
  • Control: Remote Control
  • Casing material: Galvanized steel
Unit of measurement VPA 150-2,4-1 LCD
Connected air duct size mm 150
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50
Rated power W 98
Power of electrical reheater W 2400
Unit current A 10.4
Maximum airflow m3/h 425
Sound pressure level LpA at 3 m dB(A) 29
Weight kg 52
Filter - G4
Transported air temperature (max) °С 55
Transported air temperature (min) °С -25
Ambient air temperature min °С 0
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Datasheet
"VENTS VPA" product description 01-2023
1.84 Mb
Manual
"VENTS VPA" user's manual 10-2016 (V29EN-03)
642 Kb
Manual
"VENTS VPA with control system" user's manual 10-2016 (V29-1_EN-03)
2.52 Mb
Manual
"Control Panel SYNERGY А16" user's manual 02-2016 (V131EN-01)
2.4 Mb
Certificates
Declaration of сonformity "VPA"
1.63 Mb
Certificates
Certificate GS "VPA (230V)"
186 Kb
Certificates
Certificate GS "VPA (3-400V)"
198 Kb
Certificates
Certificate LVD "VPA (230V)"
237 Kb
Certificates
Certificate LVD "VPA (3-400V)"
243 Kb
Image
VPA 150-2,4-1 LCD - image 1
416 Kb
ØD B B1 H L L1
149 455 496.5 438 800 647
Name Photo Description
Vents SR 150/600 SR 150/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 150/900 SR 150/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 150/1200 SR 150/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 150/600 SRF 150/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 150/900 SRF 150/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 150/2000 SRF 150/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 150 KOM 150 Spring-loaded backdraft damper for round ducts
Vents KRV 150 KRV 150 Air damper for air flow cut-off in round air ducts
Other accessories
Name Photo Description
Vents VVG 150 VVG 150 Flexible anti-vibration connector
Other accessories
Name Photo Description
Vents SF 397x364x70 G4 SF 397x364x70 G4 Panel filter G4