Vents VUE 100 P3B ЕС R A14

Heat recovery air handling units in heat- and sound-insulated casing
  • Maximum airflow: 170 m3/h
  • Sound pressure level LpA at 3 m: 30 dB(A)
  • Heat exchanger type: Cross flow
  • Extract filter: G4
  • Supply filter: G4 and F8 (PM2.5 93%)
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Manual
  • Control: Remote Control
  • Casing material: Coated steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUE 100 P3B ЕС R A14
Connected air duct size mm 100
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 66
Unit current A 0.5
Maximum airflow m3/h 170
Sound pressure level LpA at 3 m dB(A) 30
Heat recovery efficiency, max % 82
Heat exchanger type - Cross flow
Heat exchanger material - Enthalpy
Weight kg 17
Extract filter - G4
Supply filter - G4 and F8 (PM2.5 93%)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -15
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUE 100 P3B ЕС R A14 30 137 2016
Trademark Vents
Model VUE 100 P3B ЕС R A14
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
76.7 A+ 40 A 16.3 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 76
Maximum flow rate (m3/h) 137
Electric power input (W) 55
Reference flow rate (m3/s) 0.028
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.273
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 30
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
726 189 144
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8614 4403 1991
Datasheet
VENTS VUE P3 product description 01-2023.pdf
7.02 Mb
Datasheet
VENTS VUE P3 product description 04-2024
6.99 Mb
Datasheet
VENTS VUE P3B EC product description 01-2023
1.53 Mb
Datasheet
VENTS VUE P3B EC product description 11-2024
1.03 Mb
Manual
"VENTS VUE P3" user's manual 02-2023 (V147-EN-03)
2.22 Mb
Manual
"Sensor control panel A14/A15" user’s manual 07-2024 (V55-7EN-02)
1.21 Mb
Manual
"VENTS VUE P3B EC" user's manual 11-2023 (V146EN-05)
3.49 Mb
BIM/CAD models
VUE P3
2.15 Mb
Image
VUE 100 P3B ЕС R A14 - image 1
342 Kb
ØD A B H
99 600 481 207
Other accessories
Name Photo Description
Vents SF 200x191x20 G4 SF 200x191x20 G4 Panel filter G4
Vents SF 200x191x20 F8 SF 200x191x20 F8 F8 panel filter
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Name Photo Description
Vents KRV 100 KRV 100 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions