| Unit of measurement | VUE 180 P5B EC A14 | |
| Minimum supply voltage | V | 230 |
| Maximum supply voltage | V | 230 |
| Power supply frequency | Hz | 50/60 |
| Rated power | W | 87 |
| Unit current | A | 0.71 |
| Maximum airflow | m³/h | 220 |
| Sound pressure level LpA at 3 m | dB(A) | 33 |
| Heat recovery efficiency, max | % | 94 |
| Heat exchanger type | - | Counter flow |
| Heat exchanger material | - | Enthalpy |
| Weight | kg | 14 |
| Extract filter | - | G4 |
| Supply filter | - | G4, F7 |
| Transported air temperature (max) | °С | 40 |
| Transported air temperature (min) | °С | -25 |
| Ambient air temperature min | °С | 1 |
| Ambient air temperature max | °С | 40 |
| Ambient air humidity max | % | 60 |
| Ingress protection rating | - | IP22 |
| Ingress protection rating of the drive | - | IP44 |
| Trademark | Vents | |||||
| Model | VUE 180 P5B EC A14 | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -80.7 | A+ | -42.2 | A+ | -17.5 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | Recuperative | |||||
| Thermal efficiency of heat recovery (%) | 85 | |||||
| Maximum flow rate (m³/h) | 180 | |||||
| Electric power input (W) | 77 | |||||
| Reference flow rate (m³/s) | 0.035 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.248 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 2.7 | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU BVU | |||||
| Sound power level (dB(A)) | 49 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 713 | 176 | 131 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 8979 | 4590 | 2075 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents HV2 |
|
Humidity sensor |
| Vents CO2-1 |
|
CO2 sensors |
| Vents CO2-2 |
|
CO2 sensors |
| Vents HR-S |
|
Electro-mechanical humidistat |
| Name | Photo | Description |
|---|---|---|
| Vents KRV 150 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents Belimo LF230 |
|
The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions |
| Name | Photo | Description |
|---|---|---|
| Vents SF 214x186x18 G4 |
|
Panel filter G4 |
| Vents SF 214x186x48 F7 |
|
F7 panel filter |