Vents VUE 250 VB EC A21

Air handling units in heat- and sound-insulated casing equipped with a counter-flow enthalpy heat exchanger
  • Maximum airflow: 290 m3/h
  • Sound pressure level LpA at 3 m: 25 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4, F7
  • Sound insulation
  • Motor type: EC
  • Enthalpy heat exchanger
  • Bypass: Auto
  • Reheater: Optional
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Coated steel
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUE 250 VB EC A21
Connected air duct size mm 160
Speed - 1
Minimum supply voltage V 220
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 115
Unit current A 0.9
Maximum airflow m3/h 290
Sound pressure level LpA at 3 m dB(A) 25
Heat recovery efficiency, max % 90
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 51
Extract filter - G4
Supply filter - G4, F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
ambient air temperature min °С 1
ambient air temperature max °С 40
ambient air humidity max % 60
Ingress protection rating - IP20
Manual
"VENTS VUT/VUE 250 VB(E) EC L/R" user's manual 01-2023 (V240EN-04)
2.99 Mb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Manual
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02)
1.21 Mb
Datasheet
"VENTS VUT/VUE VB EC" product description 01-2023
9.35 Mb
Manual
"VENTS VUT/VUE 160/350/550 V(B) EC A14/A21" user's manual 10-2023 (V239EN-01)
3.2 Mb
Image
VUE 250 VB EC A21 - image 1
453 Kb
Vents VUE 250 VB EC A21 - Dimensions
ØD B H L
160 560 970 560
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Vents DPWC11200 DPWC11200 Humidity sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents NKD 160-0,8-1 A21 V.2 NKD 160-0,8-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-1,2-1 A21 V.2 NKD 160-1,2-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-1,7-1 A21 V.2 NKD 160-1,7-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 160-2,0-1 A21 V.2 NKD 160-2,0-1 A21 V.2 Duct heater for supply air post-heating with external control
Name Photo Description
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 340x170x48 G4 SF 340x170x48 G4 Panel filter G4
Vents SF 340x170x48 F7 SF 340x170x48 F7 F7 panel filter