Unit of measurement | VUE 550 PBE EC R A21 DTV | |
Connected air duct size | mm | 200 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 297 |
Power of electrical reheater | W | 2000 |
Unit current | A | 11.1 |
Maximum airflow | m3/h | 620 |
Sound pressure level LpA at 3 m | dB(A) | 30 |
Heat recovery efficiency, max | % | 87 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Enthalpy |
Weight | kg | 67 |
Extract filter | - | G4 |
Supply filter | - | G4 (F7 option) |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
∅D | B | B1 | H | L | L1 |
---|---|---|---|---|---|
200 | 827 | 960 | 280 | 1238 | 1291 |
Name | Photo | Description |
---|---|---|
Vents A22 |
![]() |
The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Vents A22 WiFi |
![]() |
The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. |
Vents A25 |
![]() |
The control panel with a sensor display |
Name | Photo | Description |
---|---|---|
Vents HV2 |
![]() |
Humidity sensor |
Vents CO2-1 |
![]() |
CO2 sensors |
Vents CO2-2 |
![]() |
CO2 sensors |
Vents HR-S |
![]() |
Electro-mechanical humidistats |
Vents DPWC11200 |
![]() |
Humidity sensor |
Name | Photo | Description |
---|---|---|
Vents DPWQ30600 |
![]() |
VOC sensors |
Vents DPWQ40200 |
![]() |
CO2 sensor |
Name | Photo | Description |
---|---|---|
Vents SR 200/600 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 200/900 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SR 200/1200 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SRF 200/600 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SRF 200/900 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Vents SRF 200/2000 |
![]() |
Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 200 |
![]() |
Spring-loaded backdraft damper for round ducts |
Vents KRV 200 |
![]() |
Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 |
![]() |
The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions |
Vents Belimo TF230 |
![]() |
The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SFK 392x236x27 G4 |
![]() |
G4 pocket filter |
Vents SFK 392x236x27 F7 |
![]() |
F7 pocket filter |
Vents SF 782x128x20 G4 |
![]() |
Panel filter G4 |
Name | Photo | Description |
---|---|---|
Vents NKP 200-1,7-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKP 200-2,0-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |
Vents NKP 200-1,2-1 A21 V.2 |
![]() |
Heater for heat exchanger freeze protection |