Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VUT 1500 EH

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional diagrams
  • Legend
Description
Description
DESCRIPTION
  • Air handling units VUT EH with electric heater are the complete air handling units designed to provide both supply and exhaust ventilation with air filtering and heat recovery.

  • The exhaust air energy is used to heat up the supply fresh air through the heat exchanger.

  • All the models are designed for connection with Ø 125, 150, 160, 200, 250, 315 mm round ducts.

MODIFICATIONS FILTER
  • VUT EH – a range of compact energy saving air handling units (AHU) equipped with supply and exhaust centrifugal fans, cross-flow heat recovery elements, electric heating coils and air filters.

  • Two incorporated G4 panel filters for extract air ventilation and F7 filters for supply air ventilation are supplied with the unit.

HEATER CASING
  • The electric heater at outlet from the heat exchanger is designed for warming up of supply air up to the set level if heat recovery is not enough to attain the set supply air temperature.

  • The casing is manufactured from aluminum-zinc compound with 25 mm thick mineral wool heat- and sound-insulating layer.

FANS  
  • The units are equipped with supply and exhaust centrifugal double-inlet fans with forward curved blades and built-in thermostat with automatic restart.

  • The electric motors and impellers are dynamically balanced in two planes.

  • The ball-bearings used with motors are designed for at least 40 000 hours operation and are maintenance-free.

HEAT EXHANGER  
  • The heat exchangers have high efficiency and are manufactured from aluminium plates. 

  • The unit is also equipped with the drain pan for condensate drainage.
CONTROL AND AUTOMATION  
  • The unit incorporates an integrated automation and control system with a multi-functional control panel with LCD display.

  • The standard delivery set includes 10 m connection cable for connection to the remote control panel.

  • The unit has the freezing protection function to prevent the heat exchanger freezing by means of actuating the bypass damper and controlling water heater.

  • As the temperature sensor warns of the freezing danger, the bypass air damper is opened and the intake air is directed through the air duct beside the heat exchanger.

  • As the heat exchanger is warmed the supply air temperature rises up to the set level while passing through the heater.

  • Meanwhile the warm extract air warms up the heat exchanger.

  • After the freezing danger is no longer imminent, the bypass damper shuts the bypass duct and the unit reverts to the standard operation mode.

VUT EH CONTROL AND PROTECTION FUNCTIONS  
  • control from the control panel: switching on/off, speed selection, timer, faults;
  • maintaining the set room temperature by the sensor on the control panel – smooth heating capacity control;
  • three-speed fan speed control (low-medium-high);
  • unit operation according to daily and week schedule (timer adjustable from the control panel);
  • safe start-up/shutdown of the fans;
  • electric heater overheating protection by the temperature sensor installed in the supply air duct and by two overheating thermostats, one thermostat activated at 60 °C with automatic reset and another thermostat activated at 90 °C with manual reset. Blowing of the heating elements for heat removing at the end of the heating cycle;
  • filter clogging control by engine hours.
ACCESSORIES FOR AIR HANDLING UNITS:  

SF

Type Replaceable filter (panel filter) G4 Replaceable filter (panel filter) F7
VUT 350 EH SF VUT 300-600 EH/WH G4 SF VUT 300-600 EH/WH F7
VUT 500 EH
VUT 530 EH
VUT 600 EH
VUT 800 EH SF VUT 1000 EH/WH G4 SF VUT 1000 EH/WH F7
VUT 1000 EH
VUT 1500 EH SF VUT 2000 EH/WH G4 SF VUT 2000 EH/WH F7
VUT 2000 EH
 
MOUNTING
 
  • The unit is designed for indoor mounting. While mounting the unit provide the correct condensate collection and drainage. 

  • Access for the unit maintenance and filter cleaning shall be provided through the side panels.
OPTIONS  
  • For attenuation of sound generated by the fans it is recommended to install the duct silencer (refer SR) from inside before the unit.
  • For vibration absorbing it is recommended to install the flexible antivibration connectors (refer VVG) on both sides of the unit.
Characteristics
Characteristics
Parameter VUT 1500 EH
Measurement unit
Heating electric heating -
Frequency 50/60 Hz
Phase 3 ˜
Engine Type 380В / 50Гц -
Voltage 400 V
Maximum fan power Maximum fan power 2шт. х 490 W
Electric heater power Electric heater power 18000 W
Air capacity 1100 m³/h
Electric heater current Electric heater current 26 A
Fan current Fan current 2шт. х 2.15 A
Total unit power 18980 W
Total unit current 30.3 A
Maximum air capacity 1750 m³/h
RPM 1100 min-1
Heat recovery efficiency 77 -
Noize level at 3 m 49 dBА
Casing material aluzinc -
Maximum transported air temperature Maximum transported air temperature -25 +45 °С
Insulation 50 mm, mineral wool -
Filter: extract G4 -
Filter: supply * option G4 (F7*) -
Connected air duct diameter 315 mm
Mass 96 kg
Heater type Heater type electric -
SEC Class - -
Connection diameter 315 mm
Heat recovery efficiency Heat recovery efficiency 77 %
Heat exchanger type cross-flow -
Heat exchanger material алюминий -
Duct connection Duct connection горизонтальное -
Type Type приточно-вытяжная с рекуперацией -
Heat recovery Heat recovery 1 -
Mounting floor mounting -
Files archieve
Downloads
Name
Certificate LVD "VUT EH" (pdf 233.04Kb)
Certificate CB Test Report "VUT EH" (pdf 19.7Mb)
Certificate GS "VUT EH" (pdf 188.26Kb)
Download high quality image "VENTS VUT EH (ErP 2016)" (psd 4.6Mb)
Brochure "VENTS VUT EH/ WH" (pdf 880.01Kb)
Declaration of сonformity "VENTS VUT EH" (pdf 1.58Mb)
User's manual "VENTS VUT EH" (pdf 3.61Mb)
Download image "VENTS VUT EH (ErP 2016)" for your website (png 513.64Kb)
User's manual “Control Panel SYNERGY А16” (pdf 2.29Mb)
Dimensions
Characteristics
VENTS  VUT 1500 EH
Parameter Value Measurement unit
B 842 mm
B1 581 mm
B2 320 mm
B3 520 mm
H 814 mm
H1 947 mm
H2 201 mm
H3 595 mm
L 1345 mm
L1 1388 mm
Additional diagrams
Additional diagrams
Sound-power level   Octave-frequency band [Hz]
  Hz   General   63   125   250   500   1000   2000   4000   8000
LwA to inlet   dBA 66 69 71 68 64 64 51 51 48
LwA to outlet dBA 69 74 71 70 62 65 63 65 56
LwA to environment dBA 43 56 59 47 44 41 35 34 30

Legend
Legend
Series   Rated air capacity [m3/h]   Heater type   Duct connection
VENTS VUT
  350; 500; 530; 600; 800; 1000; 1500; 2000   Е -  electric   H - horizontal
Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
Where have you learned about us?