VENTS VUT 160 V1B EC A14/A21


Air handling unit in heat- and sound-insulated casing. Air flow up to 200 m³/h. Heat recovery efficiency up to 93 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION  
  • The air-handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • During operation the extract air heat is transferred to the supply air stream by the highly efficient plate heat exchanger.
  • The units are designed for energy efficient ventilation of cottages and flats and are compatible with round air ducts (Ø 125, 160 and 200 mm).
FILTER FANS
  • Supply and exhaust air is purified in panel filters with filtering class G4 and F7, respectively.
  • Filters with G3 filtering class are used for supply and exhaust air purification in the VUT/VUE 200 VB EC units.
  • Supply air in the VUT/VUE 250 VB EC units is purified by the G4 and F7 filters.
  • Exhaust air is purified by the G4 filters.

  • The units are equipped with high-efficient EC motors with an external rotor and a centrifugal impeller with backward curved blades.
  • These state-of-the-art motors are the most advanced solution in energy efficiency today.
  • EC motors are characterised with high performance and optimum control across the entire speed range.
  • In addition to that, the efficiency of the electronically commutated motor reaches very impressive levels of up to 90 %.
HEAT EXCHANGER  
  • The VUT V(B) EC units are equipped with a counter-flow polystyrene heat exchanger.
  • In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses.
  • This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
  • In the warm season the ambient air heat is transferred to the exhaust air stream.
  • This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.

  • The VUE V(B) EC units are equipped with a counterflow enthalpy heat exchanger.
  • In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy heat exchanger reducing the heat losses from ventilation.
  • The ambient air heat and moisture are transferred to the exhaust air stream through the enthalpy heat exchanger in the warm season.
  • This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.


CASING BYPASS
  • Made of high-quality polymer coated steel, internally filled with 20, 25, 30 or 40 mm (depending on the unit model) mineral wool layer for heat and sound insulation.
  • The VUT/VUE VB EC units are equipped with a bypass for summer ventilation (air cooling by the cool air from outside).
AUTOMATION  
  • The VUT/VUE V(B) EC A21 are equipped with a built-in automation system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • The remote control panel is not included in the delivery set (available separately).
  • To control the unit via Wi-Fi, download the VENTS AHU mobile app.

 

  • The VUT/VUE V(B) EC A14 units have an integrated control system with a wall-mounted control panel A14 with a LED indication.
  • The VUT 200 V(B) EC, VUT 250 V EC units are available only with the A14 automation system.

FREEZE PROTECTION  
  • Freeze protection is provided by the shutdown of the supply fan.
  • In the VUT/VUE VB EC A21 units it is possible to connect a preheater to protect the unit from freezing.
CONTROL AND AUTOMATION  
Functions A21 A14
Wired remote control panel Option (А22)
А14
Wired remote LCD control panel Option (A25)
 
Wireless remote control panel Option (А22 Wi-Fi)
-
BMS RS-485
WI-FI
Ethernet
MODBUS (RTU, TCP)
-
Control by a mobile application via Wi-Fi + -
Freeze protection + +
Bypass Auto + manual Manual
Week-scheduled operation + -
Filter replacement indication According to filter timer According to filter timer
According to pressure switch of filter clogging (only for VUT/VUE 550 VB EC A21)
Alarm indication + +
Speed selection + +
Timers + -
RH% sensor Option Option
CO2 sensor Option Option
VOC sensor Option Option
PM2.5 sensor Option Option
Boost mode + -
Fireplace mode + -
Preheater connection Option -
Reheater connection Option -
Cooler connection Option -
Fire alarm sensor Option Option
Minimum supply air temperature control + -
INSTALLATION  
  • The units are designed for wall or floor mounting.
  • Access for maintenance of units and filters is possible from the right and left side.
UNIT DESIGN  

APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 160 V1B EC A14/A21
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 57 W
Maximum unit current 0.5 A
Sound pressure level at 3 m distance 22 dBА
Air capacity 200 m³/h
RPM 3770 min-1
Heat recovery efficiency 85...93 %
Transported air temperature -25 ... +40 °С
Weight 44 kg
Casing material painted steel -
Heating without heating -
Insulation 40 mm mineral wool -
Filter: extract G4 -
Filter: supply * option F7 (G4*) -
Heat exchanger material polystyrene -
Heat exchanger type counter-flow -
SEC Class A+ -
Connection diameter 125 mm
Mounting floor mounting, wall mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
User's manual "Sensor control panel PU SENS 01 A11/A19" (pdf 2.39Mb)
Brochure "VENTS VUT/VUE V(B) EC A14/A21" (pdf 8.94Mb)
Download high quality image "VENTS VUT/VUE V(B) EC A14/A21 (ErP 2015, 2016, 2018)" (psd 4.11Mb)
Download image "VENTS VUT/VUE V(B) EC A14/A21 (ErP 2015, 2016, 2018)" for your website (png 326.64Kb)
User's manual "VENTS VUT/VUE 160/350/550 V(B) EC A14/A21" (pdf 4.47Mb)
User's manual "VENTS VUT/VUE 200/250 V(B) EC A14/A21" (pdf 6.53Mb)
User’s manual "Sensor control panel A14/A15" (pdf 1.16Mb)
User’s manual "Wireless control system A21" (pdf 2.44Mb)
Dimensions
Characteristics
VENTS VUT 160 V1B EC A14/A21
Parameter Value Measurement unit
∅D 125 mm
B 370 mm
H 620 mm
L 640 mm
Additional characteristics
Additional characteristics

 

Point Power [W] Sound pressure level at 3 m distance [dBA]
1 57 24 (34)
2 56 23 (33)
3 54 23 (33)
4 28 20 (30)
5 27 20 (30)
6 26 20 (30)
7 14 13 (23)
8 13 13 (23)
9 13 13 (23)

 

A-weighted sound power level Gen. Octave frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000
LwA to supply air inlet dBA 52 28 46 49 41 35 33 36 29    
LwA to supply air outlet dBA 60 32 52 58 47 37 36 41 35    
LwA to exhaust air inlet dBA 51 27 45 49 41 36 32 35 29    
LwA to exhaust air outlet dBA 60 31 50 59 48 36 36 41 32    
LwA to environment dBA 43 23 39 39 33 29 25 25 20 22 32

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd - outdoor air temperature [°C]
textr - extract air temperature [°C]
khr - heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
Series Rated air flow [m³/h] Installation features Casing design Bypass Motor type Control
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
160, 200, 250, 300, 350, 550 V: vertical – by default
1: casing modification
_: without bypass
B: with bypass
ЕС: synchronous electronically commutated motor А14
А21
Accessories
Accessories
Model Panel filter G3 Panel filter G4 Panel filter F7 Control panel LCD Control panel Control panel with Wi-Fi Indoor humidity sensor CO2 sensor with indication CO2 sensor Humidity sensor
 
VUT 160 V ЕС A21 SF 285х195х10 G4 SF 285х195х10 F7 A25 A22 A22 Wi-Fi HV2 CO2-1 CO2-2 HR-S
VUT 160 V ЕС A14
VUE 160 V ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 160 V ЕС A14
VUT 160 VB ЕС A21 A25 A22 A22 Wi-Fi HV2
VUT 160 VB ЕС A14
VUE 160 VB ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 160 VB ЕС A14
VUT 160 V1 ЕС A21 A25 A22 A22 Wi-Fi HV2
VUT 160 V1 ЕС A14
VUE 160 V1 ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 160 V1 ЕС A14
VUT 160 V1B ЕС A21 A25 A22 A22 Wi-Fi HV2
VUT 160 V1B ЕС A14
VUE 160 V1B ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 160 V1B ЕС A14
VUT 200 V EC A14 SF 264х195х18 G3 HV2
VUT 200 VB EC A14
VUE 200 V EC A14
VUE 200 VB EC A14
VUT 250 V EC A14 SF 417х200х18 G4 SF 417х184х18 F7
VUT 250 VB EC A21 A25 A22 A22 Wi-Fi HV2
VUT 250 VB EC A14
VUE 250 V EC A14
VUE 250 VB EC A21 A25 A22 A22 Wi-Fi HV2
VUT 350 V1B ЕС A21 SF 384х196х40 G4 SF 384х196х40 F7 A25 A22 A22 Wi-Fi HV2
VUT 350 V1B ЕС A14
VUE 350 V1B ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 350 V1B ЕС A14
VUT 350 VB EC A21 SF 500х196х40 G4 SF 500х196х40 F7 A25 A22 A22 Wi-Fi HV2
VUT 350 VB EC A14
VUE 350 VB EC A21 A25 A22 A22 Wi-Fi HV2
VUE 350 VB EC A14
VUT 550 VB ЕС A21 SF 630х198х40 G4 SF 630х198х40 F7 A25 A22 A22 Wi-Fi HV2
VUT 550 VB ЕС A14
VUE 550 VB ЕС A21 A25 A22 A22 Wi-Fi HV2
VUE 550 VB ЕС A14

 

Model VOC sensor
(0-10 V)
CO2 sensor
(0-10 V)
Humidity sensor
(0-10 V)
Kitchen hood Electric heater for preheating Electric reheater Hydraulic U-trap Air damper Electric actuator Summer block
 
VUT 160 V ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 KH-1 NKP-125 NKD-125 SH-32 KRV 125 LF230 VL C6 366/285
VUT 160 V ЕС A14
VUE 160 V ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUE 160 V ЕС A14
VUT 160 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125 SH-32
VUT 160 VB ЕС A14
VUE 160 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUE 160 VB ЕС A14
VUT 160 V1 ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125 SH-32
VUT 160 V1 ЕС A14 VL C6 366/285
VUE 160 V1 ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUE 160 V1 ЕС A14
VUT 160 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125 SH-32
VUT 160 V1B ЕС A14
VUE 160 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUE 160 V1B ЕС A14
VUT 200 V EC A14 SH-32 KRV 125 VL C6 366/240
VUT 200 VB EC A14
VUE 200 V EC A14 VL C6 366/240
VUE 200 VB EC A14
VUT 250 V EC A14 SH-32 KRV 160 VL C6 366/384
VUT 250 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160
VUT 250 VB EC A14
VUE 250 V EC A14 VL C6 366/384
VUE 250 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160
VUT 350 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160 SH-32
VUT 350 V1B ЕС A14
VUE 350 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160
VUE 350 V1B ЕС A14
VUT 350 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160 SH-32
VUT 350 VB EC A14
VUE 350 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160
VUE 350 VB EC A14
VUT 550 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-200 NKD-200 SH-32 KRV 200
VUT 550 VB ЕС A14
VUE 550 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-200 NKD-200
VUE 550 VB ЕС A14
Accessories Similar products
Share your opinion
I found this page useful to select the required products easy and quick
No difficulties with the site use. Everything is logical ad clear
The site produced a nice impression

Questionnaire
Where have you learned about us?