VENTS VUT 180 P5(B) EC


Heat recovery air handling unit in sound- and heat-insulated casing. Air flow up to 220 m³/h. Heat recovery efficiency up to 98 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION  
  • The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • The extract air heat is used for warming up of the supply air stream in the high-efficient plate heat exchanger.
  • The units offer energy-efficient ventilation for cottages and flats and are compatible with round Ø 150 mm air ducts.
FILTER
  • Two built-in G4 and F7 filters provide efficient supply air filtration.
  • The G4 filter is used for extract air filtration.
CASING BYPASS
  • The casing is made of expanded polypropylene (EPP) possessing high heat- and sound-insulating properties.
  • The VUT/VUE 180 P5B EC A14/A21 units are equipped with a bypass for summer ventilation (cooling of the premise with cool outside air).
FANS  
  • High-efficient electronically commutated motors with external motor and impeller with forward curved blades.
  • Such motors are the most state-of-the-art energy saving solution.
  • EC motors are featured with high performance and total speed controllable range.
  • High efficiency reaching 90% is the premium advantage of the electronically commutated motors.
HEAT EXCHANGER  
  • The VUT 180 P5(B) EC units are equipped with a counter-flow polystyrene heat exchanger.
  • In the cold season the extract air heat is transferred to the intake air stream which reduces ventilation-generated heat losses.
  • This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
  • In the warm season the outside air heat is transferred to the exhaust air stream.
  • This allows for a considerable reduction of the supply air temperature which, in its turn, reduces the air conditioning load.

 

  • The VUE 180 P5(B) EC units are equipped with a counter-flow heat exchanger with an enthalpy at the core.
  • In the cold season the extract air heat and moisture are transferred to the exhaust air stream through the enthalpy.
  • Heat recovery minimises heat losses from ventilation.
  • In the warm season the outdoor air heat and moisture are transferred to the exhaust air stream through the enthalpy heat exchanger.
  • This enables considerable reduction of the supply air temperature and humidity which, in its turn, reduces the load on air conditioners.

 

AUTOMATION  
  • The VUT/VUE 180 P5B EC A21 units are equipped with integrated control system. The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • Remote control panel is not included in the delivery set and is available as specially ordered accessory.
  • The unit is controlled via Wi-Fi by means of the VENTS AHU mobile application that must be downloaded.
  • The VUT/VUE 180 P5B EC A14 units are equipped with integrated control system and the A14 wall-mounted control panel with LED indication.
  • The VUT/VUE 180 P5B EC A2 units are equipped with the R-1/010 speed controller.
FREEZE PROTECTION  
  • For VUT/VUE 180 P5B EC A14, VUT/VUE 180 P5 EC A2 the freeze protection is realized by means of shutdown the supply fan.
  • For VUT/VUE 180 P5B EC A21 the freeze protection is realized by means of turning the preheater on.
CONTROL AND AUTOMATION  
Functions A21 A14 A2
Wi-Fi control via mobile application + - -
Control via external wired control panel Option (A22)
А14
А2
Wired remote LCD control panel
Option (А25)
- -
Control via external wireless control panel Option (A22 Wi-Fi)
- -
BMS
RS-485
WI-FI
Ethernet
MODBUS (RTU, TCP)
- -
Service Vents Cloud Server
+
- -
Speed selection + + +
Filter replacement indication According to filter timer According to filter timer -
According to pressure switch of filter clogging - -
Alarm indication Full alarm description in the mobile application Alarm LED indication -
Week scheduled operation + - -
Bypass Auto - -
Manual Manual -
Timer + - -
Boost mode + - -
Kamin mode + - -
Freeze protection Cyclic shutdown of supply fan Cyclic shutdown of supply fan Cyclic shutdown of supply fan
Preheating (option) - -
Reheater connection Option - -
Cooler connection Option - -
Control of minimum supply air temperature + - -
Humidity control Option Option -
CO2 control Option Option -
VOC control Option - -
PM2.5 control Option - -
Fire detector Option Option -

Option. The function is available in case of mounting a respective accessory.

MOUNTING  
  • The unit is designed for suspended ceiling, wall horizontal or vertical installation using the fixing brackets.
  • The mounting position of the unit must provide service access for maintenance and repair.
UNIT DESIGN  
APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 180 P5(B) EC
A2
VUT 180 P5(B) EC
A14
VUT 180 P5(B) EC
A21
Measurement unit
Frequency 50/60 50/60 50/60 Hz
Phase 1 1 1 ˜
Voltage 230 230 230 V
Maximum unit power 87 87 87 W
Maximum unit current 0.71 0.71 0.71 A
Sound pressure level at 3 m distance 33 33 33 dBА
Air capacity 220 220 220 m³/h
RPM 2200 2200 2200 min-1
Heat recovery efficiency 86...98 86...98 86...98 %
Transported air temperature -25 ... +40 -25 ... +40 -25 ... +40 °С
Casing material expanded polypropylene expanded polypropylene expanded polypropylene -
Insulation EPP 30-15 mm EPP 30-15 mm EPP 30-15 mm -
Filter: extract G4 G4 G4 -
Filter: supply * option G4, F7 G4, F7 G4, F7 -
Connected air duct diameter 150 150 150 mm
Mass 14 14 14 kg
Heat exchanger type counter-flow counter-flow counter-flow -
Heat exchanger material polystyrol polystyrol polystyrol -
SEC Class A A+ A+ -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Name
User's manual "R-1/010" (pdf 878.83Kb)
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
Brochure "VENTS VUT/VUE 180 P5(B) EC" (pdf 1.85Mb)
User's manual "VENTS VUT/VUE 180 P5(B) EC" (pdf 2.49Mb)
Download high quality image "VENTS VUT/VUE 180 P5(B) EC (ErP 2015, 2016, 2018)" (psd 3.74Mb)
Download image "VENTS VUT/VUE 180 P5(B) EC (ErP 2015, 2016, 2018)" for your website (png 322.65Kb)
Leaflet "VENTS VUT/VUE 180 P5(B) EC" (pdf 10.87Mb)
User’s manual "Sensor control panel A14/A15" (pdf 1.16Mb)
User’s manual "Wireless control system A21" (pdf 2.44Mb)
Dimensions
Characteristics
VENTS VUT 180 P5(B) EC
Parameter Value Measurement unit
∅D 150 mm
B 600 mm
B2 326 mm
H 264 mm
L 900 mm
Additional characteristics
Additional characteristics
Point Power [W] Sound pressure level at 3 m (1 m) distance [dBA]
1 77 33 (43)
2 64 33 (43)
3 53 32 (42)
4 31 29 (39)
5 30 28 (38)
6 26 27 (37)
7 14 23 (33)
8 13 21 (31)
9 12 19 (29)

 

Exhaust air spigot configuration Air flow [l/s] Specific fan power [W/l/s] Recovery efficiency [%]
Kitchen + 1 additional wet room 21 0.90 88
Kitchen + 2 additional wet rooms 29 1.00 86
Kitchen + 3 additional wet rooms 37 1.20 85

 

A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m [dBA] LpA, 1 m [dBA]
dBA 63 125 250 500 1000 2000 4000 8000    
LwA to supply air inlet dBA 59 27 46 54 55 53 48 44 35    
LwA to supply air outlet dBA 60 27 46 54 55 52 49 44 35    
LwA to exhaust air inlet dBA 55 25 41 50 51 44 42 39 30    
LwA to exhaust air outlet dBA 55 26 41 51 51 44 42 39 31    
LwA surrounding dBA 54 18 36 47 49 48 43 37 33 33 43

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd is outdoor air temperature [°C]
textr is extract air temperature [°С]
khr is heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
Series Rated air flow [m³/h] Mounting type Casing design Bypass Motor type Control
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
180 P: supended mounting 5: expanded polypropylene _: no bypass
B: integrated bypass
ЕС: synchronous electronically commutated motor А2
А14
А21
Accessories
Accessories
Model G4 panel filter F7 panel filter  LCD control panel Control panel Wi-Fi controllable control panel Internal humidity sensor COsensor with indication CO2 sensor Humidity sensor VOC sensor (0-10 V) CO2 sensor (0-10 V) Humidity sensor (0-10 V) Reheater Preheater Syphon kit Air damper Electric actuator
VUT 180 P5B ЕС A21 SF 214x186x18 G4 SF 214x186x48 F7  А25  А22 А22 Wi-Fi HV2 CO2-1 CO2-2 HR-S DPWQ 30600 DPWQ 40200 DPWC 11200 NKD 150 NKP 150 SH-32 KRV 150 LF230
VUE 180 P5B ЕС A21
VUT 180 P5B ЕС A14 –  SH-32
VUE 180 P5B ЕС A14  
VUT 180 P5 ЕС A2  – SH-32
VUT 180 P5 ЕС A2  –