Suspended air handling units with a counterflow polystyrene or enthalpy heat exchanger
  • Maximum airflow: 220 m3/h
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4, F7
  • Sound insulation
  • Motor type: EC
  • Bypass: Manual
  • Control: Remote Control
  • Casing material: Polypropylene/Thermoplastic elastomer
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUT 180 P5B EC A14
Connected air duct size mm 150
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 87
Unit current A 0.71
Maximum airflow m3/h 220
Sound pressure level LpA at 3 m dB(A) 33
Heat recovery efficiency, max % 98
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 14
Extract filter - G4
Supply filter - G4, F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUT 180 P5B EC A14 49 180 2016
Trademark Vents
Model VUT 180 P5B EC A14
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-83.5 A+ -43.6 A+ -18.1 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 92
Maximum flow rate (m3/h) 180
Electric power input (W) 77
Reference flow rate (m3/s) 0.035
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.248
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 49
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
713 176 131
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9262 4735 2141
Datasheet
"VENTS VUT/VUE 180 P5B EC" product description 01-2023
2.64 Mb
Manual
"VENTS VUT/VUE 180 P5(B) EC" user's manual 03-2024 (V170EN-08)
2.46 Mb
Manual
"Sensor control panel A14/A15" user’s manual 07-2024 (V55-7EN-02)
1.21 Mb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
Manual
"VENTS VUT/VUE 180 P5(B) EC" user's manual 01-2023 (V170EN-07)
2.96 Mb
BIM/CAD models
VUT/VUE P5B EC
1.65 Mb
Image
VUT 180 P5B EC A14 - image 1
370 Kb
ØD ØD1 B B2 H H1 H2 L L1
150 19 600 326 264 38 302 900 1009
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Name Photo Description
Vents SH-32 SH-32 Hydraulic U-trap to drain condensate from heat exchangers and coolers
Name Photo Description
Vents KRV 150 KRV 150 Air dampers for automatic air flow control in round ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 214x186x18 G4 SF 214x186x18 G4 Panel filter G4
Vents SF 214x186x48 F7 SF 214x186x48 F7 F7 panel filter