Unit of measurement | VUT 180 P5B EC A14 | |
Connected air duct size | mm | 150 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 87 |
Unit current | A | 0.71 |
Maximum airflow | m3/h | 220 |
Sound pressure level LpA at 3 m | dB(A) | 33 |
Heat recovery efficiency, max | % | 98 |
Heat exchanger type | - | Counter flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 14 |
Extract filter | - | G4 |
Supply filter | - | G4, F7 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents | |||||
Model | VUT 180 P5B EC A14 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
-83.5 | A+ | -43.6 | A+ | -18.1 | E | |
Type of ventilation unit | Bidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | Recuperative | |||||
Thermal efficiency of heat recovery (%) | 92 | |||||
Maximum flow rate (m3/h) | 180 | |||||
Electric power input (W) | 77 | |||||
Reference flow rate (m3/s) | 0.035 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.248 | |||||
Control typology | Local demand control | |||||
Maximum internal leakage rates (%) | 2.7 | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU BVU | |||||
Sound power level (dB(A)) | 49 | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
713 | 176 | 131 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
9262 | 4735 | 2141 |
ØD | ØD1 | B | B2 | H | H1 | H2 | L | L1 |
---|---|---|---|---|---|---|---|---|
150 | 19 | 600 | 326 | 264 | 38 | 302 | 900 | 1009 |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats |
Name | Photo | Description |
---|---|---|
Vents SH-32 | The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems |
Name | Photo | Description |
---|---|---|
Vents KRV 150 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 214x186x18 G4 | Panel filter G4 | |
Vents SF 214x186x48 F7 | F7 panel filter |