Unit of measurement | VUT 2000 EH | |
Connected air duct size | mm | 315 |
Minimum supply voltage | V | 230 |
Maximum supply voltage | V | 230 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 1300 |
Power of electrical reheater | W | 18000 |
Unit current | A | 31.7 |
Maximum airflow | m3/h | 2200 |
Sound pressure level LpA at 3 m | dB(A) | 65 |
Heat recovery efficiency, max | % | 77 |
Heat exchanger type | - | Cross flow |
Heat exchanger material | - | Polystyrene |
Weight | kg | 96 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 80 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
Trademark | Vents |
Model | VUT 2000 EH |
Type of drive installed | Integrated MSD |
Type of heat recovery system | Recuperative |
Thermal efficiency of heat recovery (%) | 67 |
Nominal flow rate (m3/s) | 0.263 |
Nominal external pressure (Pa) | 293 |
Maximum internal leakage rates (%) | 2.7 |
Maximum external leakage rates (%) | 2.7 |
Static efficiency (%) | 32.4 |
Visual filter warning | See control panel catalogue data |
Effective electric power input (kW) | 0.592 |
Face velocity at design flow rate (m/s) | 1.233 |
Sound power level (dB(A)) | 85 |
Declared typology | NRVU BVU |
Energy perfomance of filters | B |
ØD | B | B1 | B2 | B3 | H | H1 | H2 | H3 | L | L1 | L2 |
---|---|---|---|---|---|---|---|---|---|---|---|
314 | 842 | 581 | 320 | 520 | 814 | 947 | 201 | 595 | 1345 | 1388 | 1445 |
Name | Photo | Description |
---|---|---|
Vents SR 315/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 315/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 315/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 315 | Spring-loaded backdraft damper for round ducts | |
Vents KR 315 | Air damper for air flow control in round air ducts |
Name | Photo | Description |
---|---|---|
Vents SF 780x273x48 G4 | Panel filter G4 | |
Vents VL C4 300/384 | Summer block |