Unit of measurement | VUT 2000 PBE EC A21 | |
Connected air duct size | mm | 315 |
Phases | - | 3 |
Minimum supply voltage | V | 400 |
Maximum supply voltage | V | 400 |
Power supply frequency | Hz | 50/60 |
Rated power | W | 1063 |
Power of electrical reheater | W | 15000 |
Unit current | A | 26.4 |
Maximum airflow | m3/h | 2100 |
Sound pressure level LpA at 3 m | dB(A) | 36 |
Heat recovery efficiency, max | % | 67 |
Heat exchanger type | - | Cross flow |
Heat exchanger material | - | Aluminum |
Weight | kg | 140 |
Extract filter | - | G4 |
Supply filter | - | G4 |
Transported air temperature (max) | °С | 40 |
Transported air temperature (min) | °С | -25 |
Ambient air temperature min | °С | 1 |
Ambient air temperature max | °С | 40 |
Ambient air humidity max | % | 60 |
Ingress protection rating | - | IP22 |
Ingress protection rating of the drive | - | IP44 |
∅D | B | H | L | L1 |
---|---|---|---|---|
315 | 950 | 762 | 1400 | 1452 |
Name | Photo | Description |
---|---|---|
Vents A22 | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A22 WiFi | The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system. | |
Vents A25 | The control panel with a sensor display |
Name | Photo | Description |
---|---|---|
Vents HV2 | Humidity sensor | |
Vents CO2-1 | CO2 sensors | |
Vents CO2-2 | CO2 sensors | |
Vents HR-S | Electro-mechanical humidistats | |
Vents DPWC11200 | Humidity sensor |
Name | Photo | Description |
---|---|---|
Vents DPWQ30600 | VOC sensors | |
Vents DPWQ40200 | CO2 sensor |
Name | Photo | Description |
---|---|---|
Vents SH-32 | The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems |
Name | Photo | Description |
---|---|---|
Vents SR 315/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 315/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SR 315/1200 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/600 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/900 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems | |
Vents SRF 315/2000 | Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems |
Name | Photo | Description |
---|---|---|
Vents KOM 315 | Spring-loaded backdraft damper for round ducts | |
Vents KRV 315 | Air damper for air flow cut-off in round air ducts |
Name | Photo | Description |
---|---|---|
Vents Belimo LF230 | The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions | |
Vents Belimo TF230 | The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions |
Name | Photo | Description |
---|---|---|
Vents SF 708x480x48 G4 | Panel filter G4 |
Name | Photo | Description |
---|---|---|
Vents NKP 315-3,0-1 A21 V.2 | Heater for heat exchanger freeze protection | |
Vents NKP 315-2,0-1 A21 V.2 | Heater for heat exchanger freeze protection |