Vents VUT 250 H mini A1

Vents VUT 250 H mini A1 - Air handling units in compact sound- and heat-insulated casing
Out of production
Air handling units in compact sound- and heat-insulated casing
  • Maximum airflow: 260 m3/h
  • Sound pressure level LpA at 3 m: 47 dB(A)
  • Heat exchanger type: Cross flow
  • Extract filter: G4
  • Supply filter: G4 (F8 PM2.5 81 %- option)
  • Sound insulation
  • Motor type: AC
  • Control: Remote Control
  • Casing material: Galvanized steel
Unit of measurement VUT 250 H mini A1
Connected air duct size mm 125
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 126
Unit current A 0.6
Maximum airflow m3/h 260
Sound pressure level LpA at 3 m dB(A) 47
Heat recovery efficiency, max % 78
Heat exchanger type - Cross flow
Heat exchanger material - Polystyrene
Weight kg 26
Extract filter - G4
Supply filter - G4 (F8 PM2.5 81 %- option)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Trademark Vents
Model VUT 250 H mini A1
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-53 A+ -22.7 D -2.6 F
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 57
Maximum flow rate (m3/h) 240
Electric power input (W) 170
Reference flow rate (m3/s) 0.056
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.63
Control typology Central demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 47
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
1152 615 570
The annual heating saved (AHS) (kWh/a) Cold Average Warm
7309 3736 1689
Datasheet
"VENTS VUT/VUE 250 V/H mini" product description 04-2024
723 Kb
Manual
"VENTS VUT(VUE) 250 V(H) mini A12 / A1" user's manual 12-2023 (V25EN-06)
8.62 Mb
BIM/CAD models
VUT/VUE mini (EC)
2.22 Mb
Image
VUT 250 H mini A1 - image 1
408 Kb
ØD B H H1 L L1
125 300 443 43 713 810
Other accessories
Name Photo Description
Vents SF 240x184x40 G4 SF 240x184x40 G4 Panel filter G4
Vents SF 240x184x40 F8 SF 240x184x40 F8 F8 panel filter
Name Photo Description
Vents SR 125/600 SR 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/900 SR 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 125/1200 SR 125/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/600 SRF 125/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/900 SRF 125/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SRF 125/2000 SRF 125/2000 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 125 KOM 125 Spring-loaded backdraft damper for round ducts
Vents KR 125 KR 125 Air damper for air flow control in round air ducts