Vents VUT 270 V5B EC А21

Heat recovery air handling units in sound- and heat-insulated casings equipped with a counter-flow polystyrene heat exchanger
  • Maximum airflow: 300 m3/h
  • Sound pressure level LpA at 3 m: 34 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4 (option F8)
  • Sound insulation
  • Motor type: EC
  • Bypass: Auto
  • Reheater: Optional
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Polypropylene/Thermoplastic elastomer
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUT 270 V5B EC А21
Connected air duct size mm 125
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 162
Unit current A 1.2
Maximum airflow m3/h 300
Sound pressure level LpA at 3 m dB(A) 34
Heat recovery efficiency, max % 98
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 13
Extract filter - G4
Supply filter - G4 (option F8)
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 60
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUT 270 V5B EC А21 50 270 2016
Trademark Vents
Model VUT 270 V5B EC А21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
81.8 A+ 42.3 A+ 17 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 90
Maximum flow rate (m3/h) 270
Electric power input (W) 153
Reference flow rate (m3/s) 0.053
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.316
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 50
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
749 212 167
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9181 4693 2122
Datasheet
"VENTS VUT/VUE 270 V5B EC" product description 01-2023
2 Mb
Manual
"VENTS VUT/VUE 270 V5(B) EC" user's manual 06-2024 (V170-1EN-09)
2.52 Mb
Manual
"VENTS VUT/VUE 270 V5(B) EC" user's manual 08-2023 (V170-1EN-08)
2.51 Mb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
BIM/CAD models
VUT/VUE V5B EC
1.02 Mb
Image
VUT 270 V5B EC А21 - image 1
443 Kb
ØD B H L
125 590 893 316
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Vents DPWC11200 DPWC11200 Humidity sensor
Name Photo Description
Vents DPWQ30600 DPWQ30600 VOC sensors
Vents DPWQ40200 DPWQ40200 CO2 sensor
Name Photo Description
Vents NKD 125-0,6-1 A21 V.2 NKD 125-0,6-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 125-0,8-1 A21 V.2 NKD 125-0,8-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKD 125-1,2-1 A21 V.2 NKD 125-1,2-1 A21 V.2 Duct heater for supply air post-heating with external control
Vents NKP 125-0,6-1 A21 V.2 NKP 125-0,6-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 125-0,8-1 A21 V.2 NKP 125-0,8-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 125-1,2-1 A21 V.2 NKP 125-1,2-1 A21 V.2 Heater for heat exchanger freeze protection
Name Photo Description
Vents SH-32 SH-32 The hydraulic U-trap for condensate drainage from heat exchangers and coolers in ventilation and air conditioning systems
Name Photo Description
Vents KRV 125 KRV 125 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo LF230 Belimo LF230 The Belimo LF series actuators are designed for controlling air dampers with cross section up to 0.8 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 264x182x18 G4 SF 264x182x18 G4 Panel filter G4
Vents SF 264x182x18 F8 SF 264x182x18 F8 F8 panel filter