Vents VUT 300 HBE EC A21

Heat recovery air handling units in sound- and heat-insulated casings equipped with a counter-flow polystyrene heat exchanger
  • Power of electrical reheater: 2800 W
  • Maximum airflow: 380 m3/h
  • Sound pressure level LpA at 3 m: 24 dB(A)
  • Heat exchanger type: Counter flow
  • Extract filter: G4
  • Supply filter: G4+F7
  • Sound insulation
  • Motor type: EC
  • Bypass: Auto
  • Reheater: Electric
  • Preheater: Optional
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Galvanized steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • VOC sensor: Optional
  • PM2.5 sensor: Optional
Unit of measurement VUT 300 HBE EC A21
Connected air duct size mm 160
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 182
Power of electrical reheater W 2800
Unit current A 13.6
Maximum airflow m3/h 380
Sound pressure level LpA at 3 m dB(A) 24
Heat recovery efficiency, max % 98
Heat exchanger type - Counter flow
Heat exchanger material - Polystyrene
Weight kg 64.3
Extract filter - G4
Supply filter - G4+F7
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ambient air humidity max % 80
Ingress protection rating - IP22
Ingress protection rating of the drive - IP44
Vents VUT 300 HBE EC A21 40 335 2016
Trademark Vents
Model VUT 300 HBE EC A21
Specific energy consumption (SEC) (kWh/(m2/a)) Cold Average Warm
-81.3 A+ -42.4 A+ -17.4 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 87
Maximum flow rate (m3/h) 335
Electric power input (W) 155
Reference flow rate (m3/s) 0.064
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m3/h)) 0.265
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Declared typology RVU BVU
Sound power level (dB(A)) 40
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
722 185 140
The annual heating saved (AHS) (kWh/a) Cold Average Warm
9060 4631 2094
Datasheet
"VENTS VUT/VUE HB/HBE EC" product description 04-2024
2.16 Mb
Manual
"VENTS VUT/VUE HB/HBE EC" user's manual 11-2023 (V109-2EN-01)
4.42 Mb
Manual
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02)
167 Kb
Manual
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05)
504 Kb
BIM/CAD models
VUT/VUE HB/HBE EC
1.56 Mb
Image
VUT 300 HBE EC A21 - image 1
444 Kb
ØD B B1 B2 H H1 H2 L L1
157 568 190 189 479 193 118 1083 1180
Name Photo Description
Vents A25 A25 The control panel with a sensor display
Vents A22 A22 The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Vents A22 WiFi A22 WiFi The A22/A22 WiFi control panels are used for control of industrial and domestic air handling units with an A21 automation system.
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistats
Name Photo Description
Vents NKP 160-0,8-1 A21 V.2 NKP 160-0,8-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,2-1 A21 V.2 NKP 160-1,2-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-1,7-1 A21 V.2 NKP 160-1,7-1 A21 V.2 Heater for heat exchanger freeze protection
Vents NKP 160-2,0-1 A21 V.2 NKP 160-2,0-1 A21 V.2 Heater for heat exchanger freeze protection
Name Photo Description
Vents SR 160/600 SR 160/600 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/900 SR 160/900 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Vents SR 160/1200 SR 160/1200 Silencer is applied for noise absorption produced during the ventilating equipment operation and spread along the ducting systems
Name Photo Description
Vents KOM 160 KOM 160 Spring-loaded backdraft damper for round ducts
Vents KRV 160 KRV 160 Air damper for air flow cut-off in round air ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 484x178x48 G4 SF 484x178x48 G4 Panel filter G4
Vents SF 484x178x48 F7 SF 484x178x48 F7 F7 panel filter